<strong>Manual</strong> – TopCon TC.GSS<br />

Appendix<br />

Error list<br />

10.2.2.11. Error group A) Internal (AD underrange 1)<br />

Group error: A) Internal (AD underrange 1)<br />

Flashing<br />

code<br />

TopControl/HMI<br />

indication<br />

11-5 A4) Output<br />

voltage<br />

underrange<br />

11-6 A5) Output<br />

current<br />

underrange<br />

11-7 A6) Sense<br />

voltage<br />

under-range<br />

11-8 A7) System<br />

voltage<br />

underrange<br />

11-9 A8) System<br />

current<br />

underrange<br />

Description<br />

AD-converter for the<br />

output voltage measurement<br />

at lower limit<br />

AD-converter for the<br />

output current measurement<br />

at lower limit<br />

AD-converter for the<br />

sense voltage measurement<br />

at lower limit<br />

AD-converter for the<br />

RMB voltage measurement<br />

at lower limit<br />

AD-converter for the<br />

RMB current measurement<br />

at lower limit<br />

Possible reason<br />

Measure to rectify<br />

Negative voltage due to controller oscillation<br />

Reduce control parameters<br />

Negative voltage due to special load conditions<br />

10<br />

After consultation with the manufacturer, it may be<br />

possible to deactivate this error message, if there is no<br />

risk for the device<br />

Negative current due to controller oscillation<br />

Reduce control parameters<br />

Negative current due to special load conditions<br />

After consultation with the manufacturer, it may be<br />

possible to deactivate this error message, if there is no<br />

risk for the device<br />

See above, error A4)<br />

See above, error A4)<br />

See above, error A5)<br />

10.2.2.12. Error group B) Internal (AD underrange 2)<br />

Group error: B) Internal (AD underrange 2)<br />

Flashing<br />

code<br />

TopControl/HMI<br />

indication<br />

12-5 B4) IGBT<br />

temperature<br />

underrange<br />

12-6 B5) Rectifier<br />

temperature<br />

underrange<br />

Description<br />

AD-converter for the<br />

IGBT or rectifier heat<br />

sink temperature sensor<br />

at lower limit<br />

Possible reason<br />

Measure to rectify<br />

Temperature sensor faulty<br />

Contact manufacturer<br />