<strong>Manual</strong> – TopCon TC.GSS<br />

TopControl application<br />

Tab – <br />

Group – “Actual values Q4” – “Booster”<br />

Visible with “Source selector” selection:<br />

“Master” or “Device” (single device).<br />

Indication of actual parameters for the booster.<br />

Fig. 101 Group – “Actual values Q4” – “Booster”<br />

STATUS tab – “Actual values Q4” group – “Booster”<br />

1<br />

2<br />

3<br />

4<br />

Temperature<br />

Heatsink Temp. Booster heat sink temperature.<br />

PCB Temp. Temperature on the circuit board for the booster.<br />

Voltages<br />

DC link voltage Intermediate circuit voltage<br />

Voltage Clamp Voltage at the charging capacitor for the booster.<br />

Supply voltages<br />

Indication of the supply voltage for the booster board.<br />

Comparison of set values and actual values.<br />

If there are large differences between the values, an error message is output.<br />

Current<br />

Current L Current in the storage choke for the booster.<br />

Current Sek Current on the secondary side of the transformer.<br />

Table 86 Group – “Actual values Q4” – “Booster”<br />