Remote Operation<br />
Command<br />
UPDN<br />
UPDT<br />
WATT<br />
WDFL<br />
Argument<br />
Update Data Now. i.e: Take a power reading when the next trigger occurs. This<br />
command is only operational if the PPM is in the Update Trigger Reset Mode. See<br />
UPDT./ The PPM will output a single data point each time UPDN is received. The<br />
output formats are the same as those described under UPDC except that each data<br />
point is not followed by a comma. Instead each point is followed by a carriage<br />
return followed by a line feed sent with EOI. If FPVO is being used, the frequency<br />
at which a power measurement was taken is output also. See UPDC and FPVO.<br />
Select Update Date Trigger Reset Output Mode. Prepares the PPM to take power<br />
readings using UPDN or GET / none<br />
Select Linear <strong>Power</strong> Format / none<br />
Measure and Output Pulse Width and Fall-times of Pulse Profile Currently<br />
Displayed. See FALL for definition of fall time. Pulse width is the time between the<br />
50% point on the pulse’s rising edge and the 50% point on it’s falling edge / When<br />
operating in channel A the PPM will output:<br />
WIDAnn.nnnEsnn,FALAnn.nnnEsnn<br />
For Channel B the output is:<br />
WIDBnn.nnnEsnn,FALBnn.nnnEsnn<br />
(n = delay in seconds; Esnn = exponent)<br />
WDLAnnnnnn.nn<br />
WDLBnnnnnn.nn<br />
ZERA<br />
ZERB<br />
*IDN?<br />
Set Channel A Delay Window / none<br />
(n = microseconds; position of decimal point may vary. 0.012 µs min; 213,999.97 -<br />
Start Delay - Reference Delay max)<br />
Set Channel B Delay Window / none<br />
(See WDLA)<br />
Autozero Channel A Detector. Takes time to complete - SRQ can monitor successful<br />
(or unsuccessful) completion / none<br />
Autozero Channel B Detector. Takes time to complete - SRQ can monitor successful<br />
(or unsuccessful) completion / none<br />
Identification Query - Output Model; Software Version. The PPM will output:<br />
<strong>Giga</strong>-<strong>tronics</strong>,8501A,0,VERnn.nn<br />
8501A = model number;<br />
0 = N/A;<br />
VER = software version;<br />
n = number of the software version. If using a Model 8502A, 8501A would be<br />
replaced by 8502A<br />