Remote Operation<br />

Command<br />

UPDN<br />

UPDT<br />

WATT<br />

WDFL<br />

Argument<br />

Update Data Now. i.e: Take a power reading when the next trigger occurs. This<br />

command is only operational if the PPM is in the Update Trigger Reset Mode. See<br />

UPDT./ The PPM will output a single data point each time UPDN is received. The<br />

output formats are the same as those described under UPDC except that each data<br />

point is not followed by a comma. Instead each point is followed by a carriage<br />

return followed by a line feed sent with EOI. If FPVO is being used, the frequency<br />

at which a power measurement was taken is output also. See UPDC and FPVO.<br />

Select Update Date Trigger Reset Output Mode. Prepares the PPM to take power<br />

readings using UPDN or GET / none<br />

Select Linear <strong>Power</strong> Format / none<br />

Measure and Output Pulse Width and Fall-times of Pulse Profile Currently<br />

Displayed. See FALL for definition of fall time. Pulse width is the time between the<br />

50% point on the pulse’s rising edge and the 50% point on it’s falling edge / When<br />

operating in channel A the PPM will output:<br />

WIDAnn.nnnEsnn,FALAnn.nnnEsnn<br />

For Channel B the output is:<br />

WIDBnn.nnnEsnn,FALBnn.nnnEsnn<br />

(n = delay in seconds; Esnn = exponent)<br />

WDLAnnnnnn.nn<br />

WDLBnnnnnn.nn<br />

ZERA<br />

ZERB<br />

*IDN?<br />

Set Channel A Delay Window / none<br />

(n = microseconds; position of decimal point may vary. 0.012 µs min; 213,999.97 -<br />

Start Delay - Reference Delay max)<br />

Set Channel B Delay Window / none<br />

(See WDLA)<br />

Autozero Channel A Detector. Takes time to complete - SRQ can monitor successful<br />

(or unsuccessful) completion / none<br />

Autozero Channel B Detector. Takes time to complete - SRQ can monitor successful<br />

(or unsuccessful) completion / none<br />

Identification Query - Output Model; Software Version. The PPM will output:<br />

<strong>Giga</strong>-<strong>tronics</strong>,8501A,0,VERnn.nn<br />

8501A = model number;<br />

0 = N/A;<br />

VER = software version;<br />

n = number of the software version. If using a Model 8502A, 8501A would be<br />

replaced by 8502A<br />

<strong>Manual</strong> No. 20790, Rev C, November 1998 3-51<br />