13.11.2014 Views

Manual - 8500A Series Peak Power Meter - Giga-tronics

Manual - 8500A Series Peak Power Meter - Giga-tronics

Manual - 8500A Series Peak Power Meter - Giga-tronics

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Summary of Commands<br />

A.6 Dual Channel Operation<br />

A.6.1<br />

A.6.2<br />

CW Mode Commands<br />

From Initial <strong>Power</strong>-On select<br />

<strong>Peak</strong> Mode Commands<br />

Assuming that there is an<br />

Autoscalable pulsed signal<br />

greater than the current trigger<br />

level at the channel A detector<br />

input, from initial <strong>Power</strong>-On<br />

select:<br />

[cw] [B]<br />

If the Dual Channel state is being entered from some other state, use the channel A<br />

and B keys. When both A and B keys are lit, the Dual Channel state has been<br />

activated.<br />

[GRAPH] [AUTOSCALE ...PEAK] [B]<br />

This method uses the Graph Mode to ensure that the cursor is placed on the pulse<br />

measured by channel A.<br />

The [GRAPH] [AUTOSCALE] keystrokes can be omitted, but this method does<br />

not guarantee that the cursor will be placed on the pulse. To find the pulse, use the<br />

procedures outlined in Method 1 of the <strong>Peak</strong> <strong>Power</strong> Measurements in Chapter 6.<br />

A.6.3<br />

A.6.4<br />

Other Dual Channel Commands<br />

Detector Offset (Channel B)<br />

Display Ratio A/B <strong>Power</strong> Mode<br />

Select <strong>Peak</strong> Mode for Channel A<br />

Select CW Mode for Channel A<br />

Select <strong>Peak</strong> Mode for Channel B<br />

Select CW Mode for Channel B<br />

Exit Ratio Mode<br />

[MENU] (3) [F2] [nn.nn] [dB]<br />

[MENU] (7) [F2]<br />

[A] [F1] (when using the Ratio Mode)<br />

[A] [F2] (when using the Ratio Mode)<br />

[B] [F1] (when using the Ratio Mode)<br />

[B] [F2] (when using the Ratio Mode)<br />

[CW] or [PEAK]<br />

IEEE & 1018B Emulation Commands<br />

Select PPM Listen and Talk<br />

Address<br />

Initiate 1018B Emulation Mode<br />

Disable/Enable Service Request*<br />

Automatic/Bus Command<br />

Trigger Reset*<br />

Get Data Fast (No EL Display)*<br />

Set Measurement Range*<br />

End 1018B Emulation Mode*<br />

[MENU] (6) [F3] [nn] [UNITS]<br />

[MENU] (8) [F2]<br />

[MENU] (8) [F1] (toggle)<br />

[MENU] (8) [F2]<br />

[MENU] (8) [F3]<br />

[MENU] (9) [F1] (for nnn.n µW)<br />

[MENU] (9) [F2] (for nn.nn mW)<br />

[MENU] (9) [F3] (for n.nnn mW)<br />

[MENU] (10) [F2]<br />

* Valid only after initiating 1018B Emulation Mode.<br />

<strong>Manual</strong> No. 20790, Rev C, November 1998 A-5<br />

Superceded by Revision D, March 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!