Testing and Calibration<br />

5.3.3 A2 Regulator Board<br />

A. +5 V Adjust<br />

1. Connect the DVM LO test lead to A2TP11.<br />

2. Connect the DVM HI test lead to A2TP9.<br />

3. Adjust A2R42 (+5V ADJ) for a DVM reading of +5.000V ±100 mV.<br />

4. Vary the Variac voltage from 100 Vac to 130 Vac. The DVM reading must not change more<br />

than ±5 mV.<br />

B. -5.2 V Check.<br />

1. Connect the DVM HI test lead to A2TP10. The DVM must read -5.200 V ±200 mV.<br />

2. Vary the Variac voltage from 100 to 130 Vac. The DVM reading must not change by more<br />

than ±5.2 mV.<br />

3. Set the Variac to 115 Vac.<br />

C. -15 V Adjust.<br />

1. Connect the DVM LO test lead to A2TP6.<br />

2. Connect the DVM HI test lead to A2TP5.<br />

3. Adjust A2R22 (-15 V ADJ) for a DVM reading of -15.000V ±15 mV.<br />

4. Vary the Variac voltage from 100 to 130 Vac. The DVM reading must not change by more<br />

than ±15 mV.<br />

D. +15 V Check.<br />

1. Connect the DVM HI test lead to A2TP3. The DVM must read +15.000 V ±45 mV.<br />

2. Vary the Variac voltage from 100 to 130 Vac. The DVM reading must not change by more than<br />

±15 mV.<br />

Turn OFF the power.<br />

Disconnect the Variac and connect the power meter to the ac power source.<br />

<strong>Manual</strong> No. 20790, Rev C, November 1998 5-11<br />

Superceded by Revision D, March 2009