8 - Configuration Tool<br />

Device Settings<br />

Tab. 8-2 Max. dilutor speeds for the LiHa (pipetting or washing)<br />

Dilutor capacity Max. dilutor speed Max. breakoff speed<br />

25 µl 21 µl/s 11 µl/s<br />

50 µl 42 µl/s 23 µl/s<br />

100 µl 83 µl/s 45 µl/s<br />

250 µl 208 µl/s 113 µl/s<br />

500 µl 417 µl/s 225 µl/s<br />

1000 µl 833 µl/s 450 µl/s<br />

2500 µl 2083 µl/s 1125 µl/s<br />

5000 µl 4167 µl/s 2250 µl/s<br />

The breakoff speed is the recommended final dilutor speed when dispensing. See<br />

10.2.2 “LiHa Dispense Parameters (Fixed Tips and DiTis)”, 10-12.<br />

If you are using the XLP dilutor pump in high resolution mode, the maximum<br />

dilutor speeds are 12.5% of the values given in the above table (<strong>Freedom</strong><br />

<strong>EVOware</strong> calculates an appropriate value for the XLP dilutor pump automatically).<br />

Offline tab<br />

Click the Offline tab to specify the required configuration of the liquid handling arm<br />

and the tip parameters if <strong>Freedom</strong> <strong>EVOware</strong> is running in offline mode. See<br />

Instrument tab, above, for a description of the parameters.<br />

Copy machine parameters<br />

Click this button to copy the current parameters from the Instrument tab to the<br />

Offline tab. This allows you to create processes and scripts in offline mode<br />

without having to specify all of the liquid handling settings manually.<br />

8.4.2.2 PosID (Moveable Barcode Scanner)<br />

This tab is used to specify custom command strings for the PosID (Positive<br />

Identification System). The PosID is a movable barcode scanner which can be<br />

used to read the barcode labels on carriers, labware and tubes. Note: The allowed<br />

barcode types are configured with the PosID command (see 15.63 “PosID<br />

Command”, 15-150). This tab is not shown if you have installed the driver for<br />

the PosID-3 barcode scanner, which supercedes the PosID barcode scanner.<br />

8 - 28 <strong>Freedom</strong> <strong>EVOware</strong> <strong>Software</strong> <strong>Manual</strong>, 393172, en, V<strong>2.3</strong>