16 - Device Commands<br />

Commands for the PW384GP Washer<br />

Vacuum level<br />

Specify the required vacuum level. The vacuum level determines the<br />

aspiration speed.<br />

Plate Type<br />

The PW384GP washer can store parameter sets for up to 15 different type of<br />

labware. The parameter sets are created using the menus on the washer’s<br />

LCD panel. Select the parameter set you want to use for aspirating. For<br />

information on parameter sets please refer to the corresponding section in the<br />

operating manual of your washer.<br />

Head position<br />

Choose the required head position when aspirating.:<br />

Bottom: The aspiration step is performed down to the bottom of the wells to<br />

ensure the minimum volume of residual liquid.<br />

Cell: The aspiration step is only performed down to a predefined height to<br />

leave a small amount of liquid in the wells. This setting is useful for cell<br />

washing. Note: The needle positions “Bottom” and “Cell” are configured in the<br />

washer with the plate parameters.<br />

Aspiration mode<br />

Select the required aspiration mode (standard or crosswise). Crosswise<br />

aspiration should only be used for 96-well plates with flat bottomed wells. In<br />

this case, aspiration is carried out with the needles at two positions in each<br />

well (front edge and back edge). This ensures the minimum volume of<br />

residual liquid. For more information, please refer to the corresponding<br />

section in the operating manual of your washer.<br />

To view or edit the execution parameters again later, right-click on the process<br />

step in the Process Editor and choose Edit Parameters in the context menu.<br />

Objects<br />

The Aspirate command operates on an object of type Sample or a derived type<br />

with default name MP.<br />

Pre-actions and Post-actions<br />

The labware is brought to the PW384GP location with a RoMa MoveObject<br />

command and brought back to its Base location with another RoMa MoveObject<br />

command.<br />

16.18.2 PW384GP Washer - Dispense Command<br />

The Dispense command starts the liquid dispensing procedure of the washer. This<br />

command is mainly intended for special applications, e.g. to fill the wells with<br />

liquid.<br />

Execution parameters<br />

You are prompted to specify the following execution parameters when you add<br />

this command to your script or process:<br />

<strong>Freedom</strong> <strong>EVOware</strong> <strong>Software</strong> <strong>Manual</strong>, 393172, en, V<strong>2.3</strong> 16 - 55