A - Appendix A<br />

<strong>Freedom</strong> EVO 75 Pipetting Instrument - LiHa Configuration<br />

Example<br />

The following command line starts <strong>Freedom</strong> <strong>EVOware</strong> with the user name David<br />

and password Long and runs the maintenance script maintscript.esc:<br />

evoware.exe -m maintscript.esc -u David -w Long<br />

Tip: In Windows, right-click on a shortcut and choose Properties > Shortcut to<br />

assign command line parameters to the shortcut.<br />

A.7 <strong>Freedom</strong> EVO 75 Pipetting Instrument - LiHa<br />

Configuration<br />

The <strong>Freedom</strong> EVO 75 pipetting instrument now supports the following LiHa<br />

configurations:<br />

• One tip.<br />

• Two tips.<br />

• 8 Plus 1 Access option.<br />

Please note the following:<br />

Two-tip LiHa<br />

You can select either or both tips in the pipetting commands. The two tips can<br />

be used for pipetting (raised or lowered) independently. The tip spacing is<br />

fixed at 18 mm (every second well of a 96-well microplate).<br />

8 Plus 1 Access option<br />

You can select either tip 1 or all 8 tips in the pipetting commands. Tip 1 can be<br />

used for pipetting (raised or lowered) independently of the other 7 tips. If you<br />

select all 8 tips, they are all used (raised or lowered) together. The tip spacing<br />

is fixed at 9 mm (adjacent wells of a 96-well microplate).<br />

In addition, liquid detection hardware is only provided for tip 1. If you want to<br />

use liquid detection, you must choose the detection mode Detect liquid with<br />

first, tip, move others to same position in the Global settings of the liquid class.<br />

The 8 Plus 1 Access option is currently only intended for disposable tips (not<br />

fixed tips). In addition, you must fit the same DITI type (DITI size) to all 8<br />

positions on the LiHa.<br />

Tip spacing<br />

Tip spreading is not available for the <strong>Freedom</strong> EVO 75 pipetting instrument (the<br />

tips have a fixed spacing of 9 or 18 mm depending on LiHa type). Accordingly, in<br />

the pipetting commands, you can only change the tip spacing setting for the 2-tip<br />

LiHa configuration. If the spacing between the wells you want to pipette is not<br />

18 mm, pipetting is carried out twice using one tip at a time.<br />

This is not possible with the 8 Plus 1 Access option. If you select all 8 tips, they<br />

are all used (raised or lowered) together. Accordingly, you cannot change the<br />

setting for tip spacing because you cannot use one tip at a time.<br />

Tip spacing is not relevant for the 1-tip LiHa configuration.<br />

Enhanced DITI logistics for the Get DITI command<br />

The following method is used to minimize LiHa movements when getting DITIs (to<br />

speed up the Get DITI commands).<br />

A - 30 <strong>Freedom</strong> <strong>EVOware</strong> <strong>Software</strong> <strong>Manual</strong>, 393172, en, V<strong>2.3</strong>