15 - Script Commands<br />

Export Data Command<br />

Tab. 15-6 Parameters in the report file output by the Export Data command<br />

Column Range Explanation<br />

Position 1 .. number of wells Destination well number or tube number. The numbering<br />

sequence is rear to front and then left to right.<br />

TubeID Max. 32 characters Barcode of destination tube. This column is only used<br />

if the destination is a tube rack (i.e. you are pipetting<br />

into tubes).<br />

In line 2, this column shows the <strong>Freedom</strong> <strong>EVOware</strong><br />

software version.<br />

ScanError 0 .. 4294967295 This column shows barcode scanning errors (if any)<br />

at the destination. See Tab. 15-7, 15-54, below.<br />

In line 2, this column shows the serial number of<br />

pipetting instrument. If you chose to include pooling<br />

balance data in the report file and a Liquid Arrival<br />

Check was carried out when dispensing, the serial<br />

number of the balance is also included in line 2 (see<br />

15.26.4 “Pooling balance data in report files”, 15-<br />

56). The two serial numbers are separated by “/”.<br />

SRCRack Max. 32 characters For dispense commands, this column shows the configuration<br />

name of the source labware.<br />

In line 2, this column shows the configuration name<br />

of the labware for which the report file was created<br />

(the configuration name of the destination labware).<br />

SRCPos 1 .. number of wells For dispense commands, this column shows the<br />

position in the source labware where the liquid came<br />

from.<br />

In line 2, this column shows the total number of wells<br />

in the labware in the x direction.<br />

SRCTubeID Max. 32 characters If the source for a dispense command was a tube<br />

rack, this column shows the barcode of the source<br />

tube.<br />

In line 2, this column shows the total number of wells<br />

in the labware in the y direction.<br />

Volume -7158278 .. +7158278 This column contains the volume in µl which was dispensed<br />

(positive value) or aspirated (negative value).<br />

dest<br />

In line 2, this column shows which pipetting step is<br />

relevant to the Tecan Magellan software if more than<br />

one has been carried out on the same well; see<br />

“Significant pipetting step for Magellan ...”, 15-49<br />

for further information.<br />

15 - 52 <strong>Freedom</strong> <strong>EVOware</strong> <strong>Software</strong> <strong>Manual</strong>, 393172, en, V<strong>2.3</strong>