15 - Script Commands<br />

Te-MO Commands<br />

Blowout airgap<br />

Specify the volume of air to aspirate directly before getting the tip block<br />

(range: 0 to 150 µl). When the tips are washed, the air is dispensed at the end<br />

of the wash procedure and serves to make sure that all of the wash liquid<br />

remaining in the tips is discarded. In contrast to the Leading Airgap (which is<br />

specified in the liquid classes), the blowout airgap is only relevant for washing<br />

the tips and is not dispensed by the Dispense command.<br />

15.56.9 Te-MO Drop Tip Block Command<br />

The Te-MO Drop Tip Block command is used to put down the tipblock at a<br />

specified position on the Te-MO.<br />

Fig. 15-93 Te-MO Drop Tip Block command<br />

The parameters of the Te-MO Drop Tip Block command are as follows:<br />

Back to source<br />

This option returns the tip block back to the Te-MO carrier and slide position<br />

from where it was fetched with the Te-MO Get Tip Block command. I:<br />

Note: If you switch off the pipetting instrument with the tip block still attached, it<br />

will forget the Te-MO carrier and slide position from where the tip block was<br />

fetched. The option Back to source will then display an error message when the<br />

script is validated.<br />

Back to position<br />

Specify the position where the Te-MO should discard the tip block by clicking<br />

on the Te-MO tip block in the Worktable Editor. The type or label (name), the<br />

Te-MO grid position and the site of the tip block are then shown in the gray<br />

(protected) fields, see also Tab. 8-9 “Te-MO 3x5 site numbers”, 8-104. You<br />

must first put a Te-MO tip block in the Worktable Editor at the required<br />

position. The gray (protected) field then shows the type or the label (name) of<br />

the selected item. You can only put Te-MO tip blocks on the middle slide of the<br />

Te-MO.<br />

15.56.10 Te-MO Refill Trough Command<br />

The Te-MO trough is a special carrier on the Te-MO which is used as a container<br />

for a reagent liquid. The reagent liquid can be aspirated using the Te-MO pipetting<br />

<strong>Freedom</strong> <strong>EVOware</strong> <strong>Software</strong> <strong>Manual</strong>, 393172, en, V<strong>2.3</strong> 15 - 135