9 - Specifying Your Instrument Setup<br />

Configuring Labware<br />

Tab. 9-21 Labware attributes, hidden (cont.)<br />

Field name Default value Description<br />

Plate type 1 Read-only field - please set this attribute with<br />

the Washer plate type field in the advanced<br />

labware settings. This variable is used by the<br />

Columbus Washer. It overwrites the plate type<br />

specified with the Columbus WashPlate<br />

device command.<br />

File (obsolete) This field is no longer used.<br />

Source barcode (Plus<br />

only)<br />

Base location<br />

Barcode ID of the mother plate<br />

Read-only field - <strong>Freedom</strong> <strong>EVOware</strong> writes<br />

the home location of the labware to this field<br />

when the labware is created.<br />

Base position 1,1,1 Read-only field - <strong>Freedom</strong> <strong>EVOware</strong> writes<br />

the labware position within the base location<br />

to this field when the labware is created.<br />

Finger type (obsolete)<br />

Location<br />

This field is no longer used.<br />

Read-only field - <strong>Freedom</strong> <strong>EVOware</strong> writes<br />

the current location of the labware to this field<br />

when the script or process is running.<br />

Position 1,1,1 Read-only field - <strong>Freedom</strong> <strong>EVOware</strong> writes<br />

the current position of the labware within the<br />

current location to this field when the script or<br />

process is running.<br />

Grip narrow 8.5 The spacing (in cm) between the RoMa grippers<br />

which should be used to grip the labware<br />

on the narrow side. To ensure a firm grip, the<br />

grippers will try to close by an additional 1 cm<br />

(this is limited by the specified grip force).<br />

Grip wide 12.5 The spacing (in cm) between the RoMa grippers<br />

which should be used to grip the labware<br />

on the wide side. To ensure a firm grip, the<br />

grippers will try to close by an additional 1 cm<br />

(this is limited by the specified grip force).<br />

Offset between<br />

stacked plates (obsolete)<br />

0,0,1 For stacked plates, distance from the bottom<br />

of the plate to the bottom of the next plate<br />

above a) . This field is no longer used.<br />

Stacker type 1 Read-only field - please set this attribute with<br />

the Stacker plate type field in the advanced<br />

labware settings.<br />