16 - Device Commands<br />

Commands for the REMP ACD96<br />

Verify barcode<br />

Check this checkbox if you want to read the 2D tube barcodes and compare<br />

them with existing barcode information in <strong>Freedom</strong> <strong>EVOware</strong>. The script or<br />

process is stopped with an error message if the barcodes do not match.<br />

16.22.2 REMP Reatrix - Initialize Command<br />

The Initialize command initializes the Reatrix. You must initialize the hardware<br />

with this command before you use other commands for this device.<br />

16.23 Commands for the REMP ACD96<br />

The REMP ACD96 Automated Capper Decapper is used to fit or remove sealing<br />

caps from REMP tubes in REMP STBR96 tube racks. Each tube rack holds 96<br />

REMP tubes. Refer to the REMP user manual for information on the rack<br />

adapters which must be used for different REMP tube rack versions.<br />

The REMP ADI software, which must be installed separately, communicates with<br />

the ACD96 through an RS232 port. The <strong>Freedom</strong> <strong>EVOware</strong> driver for the ACD96<br />

communicates with the ADI software using ActiveX.<br />

To allow <strong>Freedom</strong> <strong>EVOware</strong> to control the ACD96 device, the ADI software must<br />

be running. In addition, the ACD96 must be switched to remote mode using the<br />

function keys and menus on the device. Refer to the REMP User <strong>Manual</strong> for more<br />

information.<br />

To start the ADI software, choose Start > All Programs > Remp > Remp ADI<br />

Stand-Alone.<br />

The <strong>Freedom</strong> <strong>EVOware</strong> installation program installs <strong>Freedom</strong> <strong>EVOware</strong> drivers<br />

and a device carrier for the ACD96. The REMP ADI software installation CD is<br />

packaged with the device. The recommended program installation directory for<br />

the ADI software is C:\Program Files\Tecan\Remp<br />

REMP ADI <strong>Software</strong><br />

A single installation of the ADI software can be used to control several different<br />

REMP devices such as the ACD96 Automated Capper Decapper and the PHS<br />

Portrait Heat Sealer. After installing the ADI software, you must install driver(s) for<br />

the REMP devices you want to use.<br />

To do this, start the ADI software and choose Install New Device in the File menu.<br />

Select the required device from the list, and click Next. Then specify the device<br />

name “REMP ACD” (specify the device name exactly like this). Then click Next<br />

and click Finished in the following dialog box.<br />

Then configure the RS232 port to which the ACD96 is connected. To do this,<br />

connect the ACD96 to the PC and switch it on, switch it to remote mode using the<br />

function keys and menus on the device and choose Settings in the Device menu<br />

of the ADI software. Refer to the REMP documentation for more information.<br />

The Available Device pull-down list shows all of the device drivers which have<br />

been installed in the ADI software.<br />