13 - Overview of <strong>Freedom</strong> <strong>EVOware</strong> Commands<br />

Overview of Script Commands<br />

13.1.8 Miscellaneous Commands, Overview<br />

The following table lists the script commands for miscellaneous devices. To use<br />

these commands in <strong>Freedom</strong> <strong>EVOware</strong> Plus, add the device command “Liquid<br />

Handling Arm - Pipette” to your process; this opens the Script Editor (see<br />

16.13.2, 16-47).<br />

Tab. 13-8 Commands for miscellaneous devices<br />

Waterbath Control – The Waterbath Control command is used to control the waterbaths<br />

for the Te-Flow option. The Te-Flow option provides support for the In Situ<br />

Hybridization method. See 15.64 “Waterbath Control Command”, 15-154.<br />

Balance - The Balance command is used to read a weight from the Mettler balance<br />

and store it in a variable. See 15.65 “Balance Command”, 15-155.<br />

Balance Send Command - The Balance Send Command command allows you to<br />

send a firmware command directly to the Mettler balance. This command is only<br />

intended for specialists. See 15.66 “Balance Send Command Command”, 15-157.<br />

Send Command - The Send Command command allows you to send a firmware<br />

command directly to the pipetting instrument. This command is only intended for specialists.<br />

See 15.67 “Send Command Command”, 15-158.<br />

13.1.9 Commands for the MCA96 (Multi Channel Arm 96), Overview<br />

The following table lists the script commands for the MCA96.<br />

Tab. 13-9 Commands for the MCA96<br />

Aspirate - The MCA96 Aspirate command is used to pick up liquid from specified<br />

positions on the worktable of the pipetting instrument using the multi channel arm.<br />

See 15.68.1 “MCA96 Aspirate Command”, 15-159.<br />

Dispense - The MCA96 Dispense command is used to dispense liquid to specified<br />

positions on the worktable of the pipetting instrument using the multi channel arm.<br />

See 15.68.2 “MCA96 Dispense Command”, 15-161.<br />

Mix - The MCA96 Mix command performs a mix operation by aspirating and then dispensing<br />

at the same position using the multi channel arm. See 15.68.3 “MCA96 Mix<br />

Command”, 15-162.<br />

Wash - The MCA96 Wash command is used to wash MCA96 tips or MCA96 DITIs<br />

using the specified MCA96 wash block. See 15.68.4 “MCA96 Wash Command”,<br />

15-164.<br />

Get DITIs - The MCA96 Get DITIs command is used to pick up disposable tips for the<br />

multi channel arm from a specified position on the worktable of the pipetting instrument.<br />

See 15.68.5 “MCA96 Get DITIs Command”, 15-167.<br />

Drop DITIs - The MCA96 Drop DITIs command is used to return the disposable tips<br />

of the multi channel arm to a specified position on the worktable of the pipetting instrument.<br />

See 15.68.6 “MCA96 Drop DITIs Command”, 15-168.<br />

Get Tipblock - The MCA96 Get Tip Block command is used to pick up a tip block for<br />

the MCA96 from a specified position on the worktable of the pipetting instrument. See<br />

15.68.7 “MCA96 Get Tip Block Command”, 15-170.<br />