18 - Error Handling<br />

List of Error Messages<br />

Tab. 18-1 List of error messages (cont.)<br />

Error ID Message Text Reason Corrective Measure<br />

EVO_EVO_013_157 ROMA-vector not defined n.a. n.a.<br />

EVO_EVO_013_158<br />

ROMA-vector for this site is not<br />

defined<br />

n.a.<br />

n.a.<br />

EVO_EVO_013_159 RSP still active n.a. n.a.<br />

EVO_EVO_013_160 RSP not active n.a. n.a.<br />

EVO_EVO_013_161 RSP not active n.a. n.a.<br />

EVO_EVO_013_162 Cancel was pressed n.a. n.a.<br />

EVO_EVO_013_163 Script could not be loaded / saved n.a. n.a.<br />

EVO_EVO_013_164 Variable not defined n.a. n.a.<br />

EVO_EVO_013_165<br />

Advanced version of Evoware<br />

required<br />

n.a.<br />

n.a.<br />

EVO_EVO_013_166 No labware gripped by ROMA Labware not present<br />

Bad gripper alignment.<br />

Gripper defective.<br />

Check worktable/process<br />

definition<br />

Align/repair gripper<br />

EVO_EVO_013_167 Device not found n.a. n.a.<br />

EVO_EVO_013_168 Timeout n.a. n.a.<br />

EVO_EVO_013_169 Worklist already loaded n.a. n.a.<br />

EVO_EVO_013_170 Initialization failed PnP firmware command<br />

error<br />

EVO_EVO_013_171 Invalid command PnP firmware command<br />

error<br />

EVO_EVO_013_172 Invalid operand PnP firmware command<br />

error<br />

EVO_EVO_013_173 CAN acknowledge problems PnP firmware command<br />

error<br />

EVO_EVO_013_174 Device not implemented PnP firmware command<br />

error<br />

EVO_EVO_013_175 CAN answer timeout PnP firmware command<br />

error<br />

EVO_EVO_013_176 Device not initialized PnP firmware command<br />

error<br />

Contact your local service<br />

organization<br />

Contact your local service<br />

organization<br />

Contact your local service<br />

organization<br />

Contact your local service<br />

organization<br />

Contact your local service<br />

organization<br />

Contact your local service<br />

organization<br />

Contact your local service<br />

organization<br />

EVO_EVO_013_177<br />

Command overflow of <strong>Freedom</strong><br />

EVO control unit<br />

PnP firmware command<br />

error<br />

Contact your local service<br />

organization<br />

EVO_EVO_013_178 Plate not fetched PnP firmware command<br />

error<br />

EVO_EVO_013_179 Collision detected PnP firmware command<br />

error<br />

Contact your local service<br />

organization<br />

Contact your local service<br />

organization<br />

18 - 52 <strong>Freedom</strong> <strong>EVOware</strong> <strong>Software</strong> <strong>Manual</strong>, 393172, en, V<strong>2.3</strong>