13 - Overview of <strong>Freedom</strong> <strong>EVOware</strong> Commands<br />

Overview of Device Commands<br />

Tab. 13-20 Commands for the Heated Incubator (cont.)<br />

StartShaker - The StartShaker command starts the optional shaker of the incubator.<br />

See 16.10.3 “Heated Incubator - StartShaker Command”, 16-41.<br />

StopShaker - The StopShaker command stops the optional shaker of the incubator.<br />

See 16.10.4 “Heated Incubator - StopShaker Command”, 16-41.<br />

InsertPlate - The InsertPlate command must be used each time the RoMa inserts<br />

labware into the incubator slot. The InsertPlate command itself does not move the<br />

labware. It’s purpose is to regulate the power of the slot’s heater. See 16.10.5 “Heated<br />

Incubator - InsertPlate Command”, 16-41.<br />

RemovePlate - The RemovePlate command must be used each time the RoMa<br />

removes labware from the incubator slot. The RemovePlate command itself does not<br />

move the labware. It’s purpose is to tell <strong>Freedom</strong> <strong>EVOware</strong> to stop recording information<br />

on the slot temperature to the log file. See 16.10.6 “Heated Incubator - Remove-<br />

Plate Command”, 16-42.<br />

13.2.10 Commands for the Base Incubator, Overview<br />

The following table lists the command for the Base Incubator. The Base Incubator<br />

is a software concept and it is not a device which you can fit to your pipetting<br />

instrument. This command is not necessary in <strong>Freedom</strong> <strong>EVOware</strong> <strong>Standard</strong>.<br />

Tab. 13-21 Commands for the Base Incubator<br />

BaseIncubate - The BaseIncubate command moves the labware back to its base<br />

(labware source) position (e.g. the carousel) and leaves it there at room temperature<br />

for the specified amount of time. The base incubator is a software concept and it is not<br />

a device which you can fit to your pipetting instrument. See 16.11.1 “Base Incubator -<br />

BaseIncubate Command”, 16-44.<br />

13.2.11 Commands for the Room Temperature Incubator, Overview<br />

The following table lists the command for the Room Temperature Incubator, which<br />

is only available in <strong>Freedom</strong> <strong>EVOware</strong> Plus. The Incubate command handles<br />

incubating time and plate loading/unloading automatically.<br />

This command is not available in <strong>Freedom</strong> <strong>EVOware</strong> <strong>Standard</strong>. The labware is<br />

loaded into the room temperature incubator using RoMa movement commands.<br />

The incubating time can then be controlled by the Wait For Timer command.<br />

Tab. 13-22 Commands for the Room Temperature Incubator<br />

Incubate - The Incubate command keeps the labware at room temperature for the<br />

specified amount of time. See 16.12.1 “Room Temperature Incubator - Incubate Command”,<br />

16-45.<br />

13.2.12 Commands for the Liquid Handling Arm (LiHa), Overview<br />

The following table lists the device commands for the Liquid Handling Arm (LiHa).<br />

These commands are only available in <strong>Freedom</strong> <strong>EVOware</strong> Plus. They are not<br />

13 - 20 <strong>Freedom</strong> <strong>EVOware</strong> <strong>Software</strong> <strong>Manual</strong>, 393172, en, V<strong>2.3</strong>