SECTION 076200 - SHEET METAL FLASHING AND TRIM: continued<br />

4. ASTM A666-03 - Specification for Annealed or Cold-Worked Austenitic Stainless Steel<br />

Sheet, Strip, Plate, and Flat Bar.<br />

5. ASTM A755-03 - Specification for Steel Sheet, Metallic Coated by the Hot-Dip Process<br />

and Prepainted by the Coil-Coating Process for Exterior Exposed Building Products.<br />

6. ASTM A792-05 - Specification for Steel Sheet, 55% Aluminum-Zinc Alloy-Coated by<br />

the Hot-Dip Process.<br />

7. ASTM B32-04 - Specification for Solder Metal.<br />

8. ASTM B209-04 - Specification for Aluminum and Aluminum-Alloy Sheet and Plate.<br />

9. ASTM B370-03 - Specification for Copper Sheet and Strip for Building Construction.<br />

10. ASTM C920-02 - Specification for Elastomeric Joint Sealants.<br />

11. ASTM C1311-02 - Specification for Solvent Release Sealants.<br />

12. ASTM D226-05 - Specification for Asphalt-Saturated Organic Felt Used in Ro<strong>of</strong>ing and<br />

Waterpro<strong>of</strong>ing.<br />

13. ASTM D1187-97 (Reapproved 2002) - Specification for Asphalt-Base Emulsions for Use<br />

as Protective Coatings for Metal.<br />

14. ASTM D1970-01 - Specification for Self-Adhering Polymer Modified Bituminous Sheet<br />

Materials Used as Steep Ro<strong>of</strong>ing Underlayment for Ice Dam Protection.<br />

15. ASTM D2244-02 - Test Method for Calculation <strong>of</strong> Color Differences from<br />

Instrumentally Measured Color Coordinates.<br />

16. ASTM D4214-98 - Test Methods for Evaluating Degree <strong>of</strong> Chalking <strong>of</strong> Exterior Paint<br />

Films.<br />

17. ASTM D4397-02 - Specification for Polyethylene Sheeting for Construction, Industrial,<br />

and Agricultural Applications.<br />

18. ASTM D4586-00 - Specification for Asphalt Ro<strong>of</strong> Cement, Asbestos-Free.<br />

19. ASTM F2329-05 - Specification for Zinc Coating, Hot-Dip, Requirements for<br />

Application to Carbon and Alloy Steel Bolts, Screws, Washers, Nuts, and Special<br />

Threaded Fasteners.<br />

C. FM Global:<br />

1. FMG Loss Prevention Data Sheet 1-49-2000 - Perimeter Flashing.<br />

D. Metal Construction Association (104 S. Michigan Ave., Suite 1500, Chicago, IL 60603; (312)<br />

201-0193; www.metalconstruction.org).<br />

1. Guide Specification for Residential Metal Ro<strong>of</strong>ing, 1995.<br />

E. National Association <strong>of</strong> Architectural Metal Manufacturers:<br />

1. Metal Finishes Manual for Architectural and Metal Products, 1988.<br />

F. Sheet Metal and Air Conditioning Contractors' National Association:<br />

1. Architectural Sheet Metal Manual, 2003.<br />

1.04 PERFORMANCE REQUIREMENTS:<br />

A. General: Sheet metal flashing and trim assemblies as indicated shall withstand wind loads,<br />

structural movement, thermally induced movement, and exposure to weather without failure<br />

due to defective manufacture, fabrication, installation, or other defects in construction.<br />

Completed sheet metal flashing and trim shall not rattle, leak, or loosen, and shall remain<br />

watertight.<br />

B. Fabricate and install ro<strong>of</strong> edge flashing and copings capable <strong>of</strong> resisting the following forces<br />

according to recommendations in FMG Loss Prevention Data Sheet 1-49:<br />

1. Wind Zone 2: For velocity pressures <strong>of</strong> 31 to 45 lbf/sq. ft.: 90-lbf/sq. ft. perimeter uplift<br />

force, 120-lbf/sq. ft. corner uplift force, and 45-lbf/sq. ft. outward force.<br />

C. Thermal Movements: Provide sheet metal flashing and trim that allows for thermal<br />

movements from ambient and surface temperature changes.<br />