SECTION 096513 - RESILIENT BASE AND ACCESSORIES<br />

PART 1 - GENERAL<br />

1.01 RELATED DOCUMENTS:<br />

A. Drawings and general provisions <strong>of</strong> the Contract, including General and Supplementary<br />

Conditions and DIVISION 01 Specification Sections, apply to this Section.<br />

1.02 SUMMARY:<br />

A. Section Includes:<br />

1. Resilient base.<br />

B. Related Sections:<br />

1. DIVISION 09, Section "Resilient Tile Flooring" for resilient floor tile.<br />

1.03 REFERENCES:<br />

A. ASTM International:<br />

1. ASTM E648-03 - Test Method for Critical Radiant Flux <strong>of</strong> Floor-Covering Systems<br />

Using a Radiant Heat Energy Source.<br />

2. ASTM F710-05 - Practice for Preparing Concrete Floors to Receive Resilient Flooring.<br />

3. ASTM F1861-02 - Specification for Resilient Wall Base.<br />

4. ASTM F1869-04 - Test Method for Measuring Moisture Vapor Emission Rate <strong>of</strong><br />

Concrete Subfloor Using Anhydrous Calcium Chloride.<br />

5. ASTM F2170-02 - Test Method for Determining Relative Humidity in Concrete Floor<br />

Slabs Using in situ Probes.<br />

B. Code <strong>of</strong> Federal Regulations:<br />

1. 40 CFR 59, Subpart D-2003 - National Volatile Organic Compound Emission Standards<br />

for Architectural Coatings.<br />

1.04 SUBMITTALS:<br />

A. Product Data: For each type <strong>of</strong> product indicated.<br />

B. LEED ® Submittals:<br />

1. Product Data for Credit IEQ 4.1: For adhesives, documentation including printed<br />

statement <strong>of</strong> VOC content.<br />

2. Laboratory Test Reports for Credit IEQ 4: For adhesives, documentation indicating that<br />

products comply with the testing and product requirements <strong>of</strong> the California Department<br />

<strong>of</strong> Health Services' "Standard Practice for the Testing <strong>of</strong> Volatile Organic Emissions from<br />

Various Sources Using Small-Scale Environmental Chambers."<br />

C. Samples for Selection: For each type <strong>of</strong> product indicated.<br />

D. Samples: For each type <strong>of</strong> product indicated, in manufacturer's standard-size Samples but not<br />

less than 12 inches long, <strong>of</strong> each resilient product color, texture, and pattern required.<br />

1.05 MAINTENANCE MATERIAL SUBMITTALS:<br />

A. Furnish extra materials that match products installed and that are packaged with protective<br />

covering for storage and identified with labels describing contents.<br />

1. Furnish not less than 10 linear feet for every 500 linear feet or fraction there<strong>of</strong>, <strong>of</strong> each<br />

type, color, pattern, and size <strong>of</strong> resilient product installed.<br />

1.06 QUALITY ASSURANCE:<br />

A. Fire-Test-Response Characteristics: As determined by testing identical products according to<br />

ASTM E648 or NFPA 253 by a qualified testing agency.<br />

1. Critical Radiant Flux Classification: Class I, not less than 0.45 W/sq. cm.<br />

DEAN096513.DOC 096513-1