SECTION 265610 - EXTERIOR LIGHTING FIXTURES: continued<br />

o. Wide-Light Corp.<br />

2. High-Intensity Discharge Ballasts:<br />

a. Advance Transformer Co.<br />

b. Valmont.<br />

c. Holophane Div; Johns-Manville Corp.<br />

d. Jefferson Electric Co.<br />

e. Magne-Tek.<br />

f. McGraw-Edison Co.<br />

g. Sola Electric Div; General Signal Corp.<br />

h. Wide-Lite Corp.<br />

3. Lamps:<br />

a. General Electric.<br />

b. Osram Sylvania.<br />

c. Phillips.<br />

d. Venture.<br />

4. Solar Light Fixtures:<br />

a. SOL.<br />

2.02 EXTERIOR LIGHTING FIXTURES:<br />

A. General: Provide lighting fixtures <strong>of</strong> sizes, types, and ratings indicated; complete with, but not<br />

limited to, housings, high power factor ballasts, energy efficient ballasts, lamps, starters, and<br />

wiring. All equipment and materials shall bear the UL label.<br />

B. High-Intensity Discharge Lamp Ballasts: High power factor HID lamp ballasts rated -20ºF, <strong>of</strong><br />

ratings, types, and makes as recommended by lamp manufacturer, which properly mates and<br />

matches lamps to electrical supply by providing appropriate voltages and impedances for<br />

which lamps are designed. Design ballasts to operate lamp within the lamp's power trapezoid<br />

requirements.<br />

C. Lamps:<br />

1. Clear metal halide lamps in wattages indicated.<br />

2. Fluorescent lamps in wattages required, with lamp color as indicated on the light fixture<br />

schedule.<br />

D. Provide integral 2-50 footcandle adjustable photocell control when indicated. Photo control<br />

shall have internal 2-minute time delay.<br />

2.03 EXTERIOR LIGHTING FIXTURE TYPES:<br />

A. General: Various fixture types are indicated on the fixture schedule on the drawings. Fixtures<br />

shall comply with the minimum requirements as stated on the schedule.<br />

2.04 EXTRA STOCK:<br />

A. Furnish stock or replacement lamps amounting to 15% <strong>of</strong> the total number <strong>of</strong> lamps (but not<br />

less than four lamps in each case) <strong>of</strong> each type and size lamp used on the Project. Deliver<br />

replacement lamps as directed to Contracting Officer's storage space and obtain a receipt.<br />

PART 3 - EXECUTION<br />

3.01 EXAMINATION:<br />

DEAN265610.DOC 265610-3