SECTION 124813 - ENTRANCE FLOOR MATS AND FRAMES<br />

PART 1 - GENERAL<br />

1.01 RELATED DOCUMENTS:<br />

A. Drawings and general provisions <strong>of</strong> the Contract, including General and Supplementary<br />

Conditions and DIVISION 01 Specification Sections, apply to this Section.<br />

1.02 SUMMARY:<br />

A. This Section includes the following:<br />

1. Entrance mats in recessed frames.<br />

B. Related Sections include the following:<br />

1. DIVISION 03 Section "Cast-in-Place Concrete" for slab depression grouting and filling<br />

for recessed mats and frames.<br />

1.03 REFERENCES:<br />

A. American Architectural Manufacturers Association:<br />

1. AAMA 611 (1998) - Voluntary <strong>Specifications</strong> for Anodized Architectural Aluminum.<br />

B. ASTM International:<br />

1. ASTM B221-08 - Specification for Aluminum and Aluminum-Alloy Extruded Bars,<br />

Rods, Wire, Pr<strong>of</strong>iles, and Tubes.<br />

2. ASTM B455-05 - Specification for Copper-Zinc-Lead Alloy (Leaded-Brass) Extruded<br />

Shapes.<br />

C. International Code Council:<br />

1. ICC A117.1 (2003) - Accessible and Usable Buildings and Facilities (ANSI).<br />

D. National Association <strong>of</strong> Architectural Metal Manufacturers:<br />

1. Metal Finishes Manual for Architectural and Metal Products, 2006.<br />

E. U.S. Architectural & Transportation Barriers Compliance Board:<br />

1. Americans with Disabilities Act (ADA) and Architectural Barriers Act (ABA)<br />

Accessibility Guidelines for Buildings and Facilities. Adopted in 2004.<br />

1.04 SUBMITTALS:<br />

A. Product Data: Include construction details, material descriptions, dimensions <strong>of</strong> individual<br />

components and pr<strong>of</strong>iles, and finishes.<br />

B. Shop Drawings: Show the following:<br />

1. Perimeter floor moldings.<br />

C. Samples: For each type <strong>of</strong> product indicated.<br />

1. Floor Mat: 12-inch square, assembled sections <strong>of</strong> floor mat.<br />

2. Tread Rail: 12-inch long Sample <strong>of</strong> each type and color.<br />

3. Frame Members: 12-inch long Sample <strong>of</strong> each type and color.<br />

1.05 CLOSEOUT SUBMITTALS:<br />

A. Maintenance Data: For floor mats and frames to include in maintenance manuals.<br />

1.06 MAINTENANCE MATERIAL SUBMITTALS:<br />

A. Furnish extra materials described below that match products installed and that are packaged<br />

with protective covering for storage and identified with labels describing contents.<br />

1. Entrance Tiles: Full-size units equal to 2% <strong>of</strong> amount installed for each size, color, and<br />

pattern indicated, but no fewer than 10 units.<br />

DEAN124813.DOC 124813-1