SECTION 076200 - SHEET METAL FLASHING AND TRIM: continued<br />

flat-stock gutter spacers and gutter brackets fabricated from same metal as gutters, <strong>of</strong> size<br />

recommended by SMACNA but not less than twice the gutter thickness. Fabricate expansion<br />

joints, expansion-joint covers, gutter bead reinforcing bars, and gutter accessories from same<br />

metal as gutters.<br />

1. Gutter Style: SMACNA designation A.<br />

2. Expansion Joints: Butt type.<br />

3. Accessories: Wire ball downspout strainer.<br />

4. Gutters with Girth up to 15 Inches: Fabricate from the following materials:<br />

a. Coil coated galvanized steel, minimum 22 gage.<br />

B. Downspouts: Fabricate rectangular downspouts complete with mitered elbows. Furnish with<br />

metal hangers, from same material as downspouts, and anchors.<br />

1. Fabricated Hanger Style: SMACNA figure designation 1-35A.<br />

2. Fabricate from the following materials:<br />

a. Coil coated galvanized steel, minimum 22 gage.<br />

C. Scuppers: Fabricate from the following materials:<br />

1. Coil coated galvanized steel, minimum 22 gage.<br />

2. Minimum size: 4 inches deep by 8 inches wide by 8 inches high.<br />

2.06 LOW-SLOPE ROOF SHEET METAL FABRICATIONS:<br />

A. Ro<strong>of</strong>-Edge Flashing (Gravel Stop) and Fascia Cap: Fabricate in minimum 96 inch long, but<br />

not exceeding 10 foot long, sections. Furnish with 6 inch wide, joint cover plates.<br />

2.07 PRECAST CONCRETE SPLASH BLOCKS:<br />

A. Splash blocks shall be factory-made units from a plant regularly engaged in producing precast<br />

concrete splash blocks.<br />

B. Concrete shall be minimum 3,000 psi using 1/2 inch to No. 4 nominal-size coarse aggregate,<br />

with minimum reinforcement required for handling <strong>of</strong> the units. Minimum clearance <strong>of</strong><br />

3/4 inch shall be maintained between reinforcement and faces <strong>of</strong> units.<br />

C. Exposed-to-view surfaces shall be free <strong>of</strong> surface voids, spalls, cracks, and chipped or broken<br />

edges and shall be <strong>of</strong> uniform appearance and color. Units shall have a smooth dense finish.<br />

D. Splash blocks shall be 18 inches wide by 36 inches long by 4 inches high. Minimum thickness<br />

shall be 2 inches.<br />

2.08 SOFFIT PANELS:<br />

A. Materials and Finishes:<br />

1. Panel Materials: 0.032 inch, 3105 H14 or equivalent (20 ksi yield strength) aluminum<br />

alloy conforming to ASTM B209 and meeting the requirements <strong>of</strong> AAMA 1402-86.<br />

2. Texture: Smooth.<br />

3. Pr<strong>of</strong>ile: 12 inch wide panels, 3/8 inch deep, with double 5.5 inch wide faces forming<br />

V-grooves at 6 inches on center. Other panels providing similar pr<strong>of</strong>iles are acceptable.<br />

4. Supply ventilating s<strong>of</strong>fit panels having perforations: 1/16 inch diameter holes on<br />

5/32 inch staggered centers in a uniform 5 inch wide pattern along entire panel length.<br />

5. Finish: Factory-applied Kynar® 500/Hylar® 5,000* coating.<br />

B. Accessories:<br />

1. Flashing and Trim: Flashing and trim shall be <strong>of</strong> the same material, gauge, finish, and<br />

color as the s<strong>of</strong>fit panels and fabricated in accordance with standard SMACNA<br />

procedures and details.<br />

2. Fasteners: Exposed screws shall be aluminum or stainless steel with a neoprene washer.<br />

076200-6 DEAN076200.DOC