SECTION 085113 - ALUMINUM WINDOWS: continued<br />

calculation on surface temperatures <strong>of</strong> materials due to both solar heat gain and nighttime-sky<br />

heat loss.<br />

1. Temperature Change: 120ºF, ambient; 180ºF material surfaces.<br />

G. Sound Transmission Class (STC): Rated for not less than 26 STC when tested for laboratory<br />

sound transmission loss according to ASTM E90 and determined by ASTM E413.<br />

H. Outside-Inside Transmission Class (OITC): Rated for not less than 22 OITC when tested for<br />

laboratory sound transmission loss according to ASTM E90 and determined by ASTM E1332.<br />

I. Windborne-Debris Resistance: Capable <strong>of</strong> resisting impact from windborne debris based on<br />

testing glazed windows identical to those specified, according to ASTM E1886 and testing<br />

information in ASTM E1996 and requirements <strong>of</strong> authorities having jurisdiction.<br />

J. Blast Resistance:<br />

1. Provide aluminum windows with framing members capable <strong>of</strong> withstanding a uniform<br />

static pressure applied to all glazing surfaces equal to the equivalent 3-second duration<br />

design loading determined in accordance with ASTM F2248 using explosive weight I as<br />

specified in UFC 4-010-02 and a stand<strong>of</strong>f distance <strong>of</strong> 148 ft.<br />

a. Framing members shall restrict edge deflections <strong>of</strong> glazing panes to 1/160 <strong>of</strong> the<br />

supported edge length, as determined in accordance with UFC 4-010-01, at<br />

allowable stress levels under the equivalent 3-second duration design loading.<br />

2. Provide aluminum window connections to surrounding structural elements, hardware and<br />

associated connections, and glazing stop connections capable <strong>of</strong> withstanding a uniform<br />

static pressure applied to all glazing surfaces equal to two times the equivalent 3-second<br />

duration design loading determined in accordance with ASTM F2248 using explosive<br />

weight I as specified in UFC 4-010-02 and a stand<strong>of</strong>f distance <strong>of</strong> 148 ft.<br />

a. Design <strong>of</strong> connections shall be based upon allowable stress levels. Allowable<br />

fastener loads shall be as recommended by the manufacturer for the materials to<br />

which glazing systems are being connected.<br />

b. Connections shall be capable <strong>of</strong> preventing the frame from being dislodged from the<br />

supporting structural elements, as demonstrated by calculation or testing in<br />

accordance with UFC 4-010-01.<br />

3. As an alternative to the requirements specified above, provide aluminum windows that<br />

have been tested in accordance with ASTM F1642 and received a hazard rating <strong>of</strong> Very<br />

Low or better for the peak pressure and positive phase impulse that correspond to each <strong>of</strong><br />

the following:<br />

a. Explosive weight I as specified in UFC 4-010-02 at a stand<strong>of</strong>f distance <strong>of</strong> 148 ft.<br />

b. Explosive weight II as specified in UFC 4-010-02 at a stand<strong>of</strong>f distance <strong>of</strong> 82 ft.<br />

2.03 ALUMINUM WINDOWS:<br />

A. Operating Types: Provide the following operating types in locations indicated on Drawings:<br />

1. Fixed.<br />

B. Frames: Aluminum extrusions complying with AAMA/WDMA/CSA 101/I.S.2/A440.<br />

1. Thermally Improved Construction: Fabricate frames with an integral, concealed, lowconductance<br />

thermal barrier located between exterior materials and window members<br />

exposed on interior side in a manner that eliminates direct metal-to-metal contact.<br />

C. Glass: Clear annealed glass, ASTM C1036, Type 1, Class 1, q3.<br />

1. Kind: Fully tempered.<br />

D. Insulating-Glass Units: ASTM E2190, certified through IGCC as complying with<br />

requirements <strong>of</strong> IGCC. See SECTION 088000 - GLAZING.<br />

E. Glazing System: Manufacturer's standard factory-glazing system that produces weathertight<br />

seal.<br />

DEAN085113.DOC 085113-5