SECTION 133423 - FABRICATED STRUCTURES: continued<br />

15. ASTM E774-97 - Specification for the Classification <strong>of</strong> the Durability <strong>of</strong> Sealed<br />

Insulating Glass Units.<br />

16. ASTM F2329-05 - Specification for Zinc Coating, Hot-Dip, Requirements for<br />

Applications to Carbon and Alloy Steel Bolts, Screws, Washers, Nuts and Special<br />

Threaded Fasteners.<br />

F. Code <strong>of</strong> Federal Regulations:<br />

1. 16 CFR 1201-2005 - Safety Standard for Architectural Glazing Materials.<br />

G. Department <strong>of</strong> Commerce:<br />

1. DOC PS 1-1995 - Construction and Industrial Plywood.<br />

H. National Association <strong>of</strong> Architectural Metal Manufacturers:<br />

1. Metal Finishes Manual for Architectural and Metal Products, 1988.<br />

I. NFPA:<br />

1. NFPA 70-2005 - National Electrical Code.<br />

1.04 PERFORMANCE REQUIREMENTS:<br />

A. Structural Performance: Control booths shall withstand the effects <strong>of</strong> gravity loads and the<br />

following loads and stresses within limits and under conditions indicated according to:<br />

1. Dead Loads: Per IBC.<br />

2. Live Loads: Per IBC.<br />

3. Ro<strong>of</strong> Loads: 20 psf.<br />

4. Snow Loads: 13 psf (flat-ro<strong>of</strong>).<br />

5. Seismic Design Category: B.<br />

6. Wind Loads: 115 mph with 3-second gust.<br />

7. Deflection Limits: Design framing system to withstand design loads without deflections<br />

greater than the following:<br />

a. Per IBC.<br />

B. Thermal Movements: Allow for thermal movements from ambient and surface temperature<br />

changes. Base calculations on surface temperatures <strong>of</strong> materials due to both solar heat gain<br />

and nighttime-sky heat loss.<br />

1. Temperature Change (Range): 120ºF, ambient; 180ºF, material surfaces.<br />

1.05 SUBMITTALS:<br />

A. Product Data: For each type <strong>of</strong> product indicated. Include construction details, material<br />

descriptions, dimensions <strong>of</strong> individual components and pr<strong>of</strong>iles, and finishes for control<br />

booths.<br />

B. Shop Drawings: For control booths. Include plans, elevations, sections, details, and<br />

attachments to other work.<br />

C. Samples for Verification: For exposed finishes, in manufacturer's standard sizes.<br />

1.06 INFORMATIONAL SUBMITTALS:<br />

A. Welding certificates.<br />

B. Warranty: Sample <strong>of</strong> special warranty.<br />

1.07 CLOSEOUT SUBMITTALS:<br />

A. Maintenance Data: For control booths to include in maintenance manuals.<br />

1.08 QUALITY ASSURANCE:<br />

A. Welding Qualifications: Qualify procedures and personnel according to the following:<br />

1. AWS D1.1, "Structural Welding Code - Steel."<br />

133423-2 DEAN133423.DOC