<strong>Electra</strong> <strong>Elite</strong> <strong>IPK</strong> Document Revision 4<br />

1-4-15 Automated Attendant Message Access<br />

Code (2-Digit) Assignment<br />

General Description<br />

Use this Memory Block to specify a 2-digit code to route an incoming call from the<br />

Automated Attendant.<br />

Display<br />

<strong>Programming</strong> Procedures<br />

1 Go off-line.<br />

Data<br />

No.<br />

2 Press LK1 + LK4 +JJAEto access the Memory Block.<br />

3 Use the dial pad to enter Function Code for MSG. 1, Dial No. 00.<br />

Use the following to enter data:<br />

�<br />

K~Hto enter Automated Attendant message number<br />

Related <strong>Programming</strong><br />

Title<br />

MSG. AA<br />

(1~8)<br />

Dial.<br />

No.<br />

00~99<br />

1 5 : A A A C 1 – 0 O = 0 3 0<br />

T I M E D I S P L A Y<br />

KK~IIto enter Dial No.<br />

Function<br />

Code<br />

4 Press G to write the data and to advance the Dial No.<br />

5 Repeat Steps 3 and 4 for each Dial No. Message 2, Dial No. 00 is displayed.<br />

6 Continue this cycle until the Dial number function codes are assigned to all AA MSGs. The next Memory Block is displayed.<br />

7 Program the next Memory Block or press E to go back on-line.<br />

Default Values<br />

Refer to individual features in the <strong>Electra</strong> <strong>Elite</strong> <strong>IPK</strong> Features and Specifications <strong>Manual</strong>.<br />

System Mode<br />

1<br />

Submode<br />

4<br />

Data No.<br />

15<br />

PC <strong>Programming</strong><br />

�+AU<br />

Dial No. Funct. Code Contents<br />

00 ~ 50 030 Specified Station Call (0)<br />

51 011<br />

Bypass Automated<br />

Attendant<br />

52 015 Paging Zone A Call<br />

53 016 Paging Zone B Call<br />

54 017 Paging Zone C Call<br />

55 ~ 99 000 Not Used<br />

Notes �<br />

�<br />

To use default 52~54, ringing must be assigned in Memory Blocks 4-01 [CO/PBX Ring Assignment (Day Mode)]<br />

or 4-02 [CO/PBX Ring Assignment (Night Mode)].<br />

___________________________________________________________________________________<br />

<strong>Programming</strong> <strong>Manual</strong> 2 - 169