<strong>Electra</strong> <strong>Elite</strong> <strong>IPK</strong> Document Revision 4<br />

LK 1 System Mode<br />

Data<br />

No.<br />

LK 15 K-CCIS<br />

Memory Block Name Default Value <strong>Programming</strong> Values<br />

00 K-CCIS Main/Remote Office<br />

Selection<br />

01 Common Signal Channel Data<br />

Speed Assignment<br />

02 Common Signal Channel<br />

Assignment<br />

NONE NONE, MAIN, REMOTE<br />

56k 64k, 56k, 48k(1), 48k(2)<br />

00 Any DTI Trunk<br />

03 Originating Point Code Assignment Blank Point Code Range: 00001~16367<br />

04 Destination Point Code Assignment Blank Point Code Range: 00001~16367<br />

05 Destination Point Code Transfer<br />

Assignment<br />

06 Originating Office code Number<br />

Assignment<br />

07 K-CCIS Message Response<br />

Timeout Assignment<br />

08 Link Reconnect Allow/Deny<br />

Selection<br />

09 K-CCIS Maximum Call Forwarding<br />

Hop Assignment<br />

10 Calling Name display Allow/Deny<br />

Selection<br />

11 Centralized Billing Allow/Deny<br />

Selection<br />

12 Centralized Billing – Point Code of<br />

Center Office Assignment<br />

13 Centralized Day/Night Switching for<br />

Remote Office Assignment<br />

14 Centralized Day/Night Switching for<br />

Main Office Assignment<br />

15 Centralized BLF Send Point Code<br />

Assignment<br />

Blank Point Code Range: 00001~16367<br />

T001~T255 can be assigned.<br />

Blank Valid Range: 0~99999<br />

30 sec Valid Times: 01~99 Seconds<br />

YS NO, YS<br />

5 1~7<br />

NO NO, YS<br />

NO (Deny) NO (Deny), YS (Allow)<br />

Blank Point Code Range: 00001~16367<br />

NO (Deny) NO (Deny), YS (Allow)<br />

All Tables Not<br />

Specified<br />

All Tables Not<br />

Specified<br />

Table Range: 01~16<br />

Point Code Range: 00001~16367<br />

Group No. 1~8<br />

Point Code Range: 00001~16367<br />

___________________________________________________________________________________<br />