<strong>Electra</strong> <strong>Elite</strong> <strong>IPK</strong> Document Revision 4<br />

Display (R3000 or higher)<br />

Data<br />

No.<br />

<strong>Programming</strong> Procedures<br />

1 Go off-line.<br />

2 Press LK1 + LK7 + KF to access the Memory Block.<br />

3 Use the dial pad to enter the Data Setting for Class 1.<br />

Setting Data<br />

000s~999s (e.g., 300s = 5m)<br />

4 Press G to write the data and display the next Timer Class of Service.<br />

5 Program the next Timer Class of Service or press E to go back on-line.<br />

Related <strong>Programming</strong><br />

Title<br />

M.B. Number Memory Block Name<br />

1-2-00 Internal Paging Timeout Selection<br />

1-7-02 External Speaker Connection Selection<br />

4-71 Station to Timer Class of Service (R3000 or higher)<br />

1. Types of paging include:<br />

� All Internal Zone (51)<br />

Timer<br />

Class<br />

� Internal Zone Paging (52~54)<br />

� Notes �<br />

� External Zone Paging (all speakers) (55)<br />

� External Zone Paging (individual speakers) (56~58)<br />

1~4<br />

0 6 : E S P T M R 1 = 3 0 0 s<br />

T I M E D I S P L A Y<br />

Setting<br />

Data<br />

Default Values<br />

Class 1~4 = 300s<br />

000S = No Limit<br />

� Internal/External Zone Paging (59)<br />

2. <strong>Telephone</strong> ports 1 and 2 are in Station to Timer Class of Service, Class 1 by default. All other ports are in<br />

Station to Timer Class of Service, Class 2 by default (R3000 or higher).<br />

3. When a system is upgraded from R2500 or lower to R3000 or higher, the External Paging Timeout Selection is<br />

reset to the default value during the upgrade process.<br />

___________________________________________________________________________________<br />

<strong>Programming</strong> <strong>Manual</strong> 2 - 201