Document Revision 4 <strong>Electra</strong> <strong>Elite</strong> <strong>IPK</strong><br />

___________________________________________________________________________________<br />

Page 7 – Trunks 49~56<br />

LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8<br />

49 50 51 52 53 54 55 56<br />

Page 8 – Trunks 57~64<br />

LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8<br />

57 58 59 60 61 62 63 64<br />

<strong>Programming</strong> Procedures<br />

1 Go off-line.<br />

2 Press LK4 to access the Memory Block.<br />

3 Press the CO/PBX Line key to select Day ring assignment for Tel Port No.<br />

The LED indication changes to indicate data each time a CO/PBX line key is pressed.<br />

CO/PBX<br />

Line Key LED<br />

Data No ring<br />

Use the following to enter data:<br />

�<br />

Jto move the cursor left<br />

Lto move the cursor right<br />

K~Ito enter numeric data or Tel Port No.<br />

– OR –<br />

D to go to next assigned Tel Port No.<br />

C to go to the next page<br />

A to go to the previous page<br />

4 Press G to write the data and display Memory Block 4-02.<br />

Default Values<br />

5 After programming Memory Blocks 4-02~4-59, the next sequential Tel Port No. is automatically displayed.<br />

6 Repeat steps 3, 4, and 5 until all Tel Port Nos. are programmed. Tel Port No. 01 is displayed again.<br />

7 Press E to go back on-line.<br />

Off Green Red<br />

Immediate<br />

Ring<br />

Delayed Ring<br />

<strong>Telephone</strong> ports A0~C0 are ports 100~120. Refer to Settings 1 to enter ports A0~C0.<br />

� Notes �<br />

CO/PBX lines 01 ~ 08 ring at Tel Port<br />

numbers 01 and 02.<br />

Tel Port numbers 03 ~ 120 do not ring<br />

on any incoming CO/PBX calls.<br />