10.02.2013 Views

Electra Elite IPK Programming Manual - Southwestern Telephone ...

Electra Elite IPK Programming Manual - Southwestern Telephone ...

Electra Elite IPK Programming Manual - Southwestern Telephone ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

___________________________________________________________________________________<br />

<strong>Electra</strong> <strong>Elite</strong> <strong>IPK</strong> Document Revision 4<br />

Display (R3000 or higher)<br />

Data<br />

No.<br />

<strong>Programming</strong> Procedures<br />

1 Go off-line.<br />

2 Press LK1 + LK1 +KCto access the Memory Block.<br />

3 Use the dial pad to enter the Data Setting for Class 1.<br />

Setting Data<br />

000s~255s (e.g., 045s = 45s)<br />

4 Press G to write the data and display the next Timer Class of Service.<br />

5 Program the next Timer Class of Service or press E to go back on-line.<br />

Related <strong>Programming</strong><br />

Title<br />

M.B. Number Memory Block Name<br />

Timer<br />

Class<br />

1-1-63 Hold Recall Time Selection (Exclusive)<br />

1-2-23 System Call Park Recall Time Selection<br />

4-71 Station to Timer Class of Service (R3000 or higher)<br />

1~4<br />

0 3 : H L D R C L 1 = 0 6 0 s<br />

T I M E D I S P L A Y<br />

Setting<br />

Data<br />

� Notes �<br />

Default Values<br />

Class 1~4 = 060s<br />

000s = No Limit<br />

1. Calls put on Exclusive Hold, recall using the data selected in Memory Block 1-1-63 [Hold Recall Time Selection<br />

(Exclusive)].<br />

2. Calls placed on hold on Call Appearance keys, recall using this Memory Block.<br />

3. Calls parked in System Call Park locations recall using Memory Block 1-2-23 (System Call Park Recall Time<br />

Selection).<br />

4. <strong>Telephone</strong> ports 1 and 2 are in Station to Timer Class of Service, Class 1 by default. All other ports are in Station<br />

to Timer Class of Service, Class 2 by default (R3000 or higher).<br />

5. When a system is upgraded from R2500 or lower, the Hold Recall Time Selection is reset to the default value<br />

during the upgrade process (R3000 or higher).<br />

___________________________________________________________________________________<br />

<strong>Programming</strong> <strong>Manual</strong> 2 - 7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!