<strong>Electra</strong> <strong>Elite</strong> <strong>IPK</strong> Document Revision 4<br />

___________________________________________________________________________________<br />

Display (3000 or higher)<br />

CO/PBX<br />

No.<br />

(01~64)<br />

<strong>Programming</strong> Procedures<br />

1 Go off-line.<br />

Data<br />

No.<br />

2 Press LK3 + G + FA to access the Memory Block.<br />

3 Use the dial pad to enter the Data Setting for Class 1.<br />

Setting Data<br />

00s~99s (e.g., 02s = 2s)<br />

4 Press G to write the data and display the next memory block.<br />

5 Program the next memory block, or press E to go back on-line.<br />

Related <strong>Programming</strong><br />

M.B. Number Memory Block Name<br />

3-42 DIT Assignment<br />

3-43 ANA Assignment<br />

Title<br />

0 1 / 6 1 : D L Y A N S 0 0 s<br />

T I M E D I S P L A Y<br />

3-62 DIT Tenant Assignment<br />

Setting<br />

Data<br />

� Notes �<br />

Default Values<br />

00s<br />

00s = No Time<br />

1. When the time is set to a value other than 0, call termination is treated as a normal incoming call and DIT<br />

termination is performed after the time elapses. When 0 is selected, DIT call termination is performed<br />

immediately.<br />

2. R3000 or higher is required to adjust this memory block by 1-second intervals.<br />

___________________________________________________________________________________<br />

<strong>Programming</strong> <strong>Manual</strong> 2 - 483