___________________________________________________________________________________<br />

Document Revision 4 <strong>Electra</strong> <strong>Elite</strong> <strong>IPK</strong><br />

Display (R3000 or higher)<br />

Data<br />

No.<br />

<strong>Programming</strong> Procedures<br />

1 Go off-line.<br />

2 Press LK1 + LK1 +KEto access the Memory Block.<br />

3 Use the dial pad to enter the Data Setting for Class 1.<br />

Setting Data<br />

00s~99s (e.g., 02s = 2s)<br />

4 Press G to write the data and display the next Timer Class of Service.<br />

5 Program the next Timer Class of Service or press E to go back on-line.<br />

Related <strong>Programming</strong><br />

Title<br />

M.B. Number Memory Block Name<br />

Timer<br />

Class<br />

0 5 : S T A R T 1 = 0 2 s<br />

T I M E D I S P L A Y<br />

1-5-25 SMDR Valid Call Time Assignment<br />

4-71 Station to Timer Class of Service (R3000 or higher)<br />

1. This time is used for the features with functions described below:<br />

� Notes �<br />

Default Values<br />

Class 1~4 = 02s<br />

00s = No Limit<br />

Elapsed Call Time: The time after dialing before the Elapsed Call Time is started and displayed on a Multiline<br />

Terminal.<br />

SMDR Start Time: The time needed after dialing before the SMDR Valid Call Time is started. Refer to Memory<br />

Block 1-5-25 (SMDR Valid Call Time Assignment). For outgoing calls, both Elapsed Call Time and SMDR Valid<br />

Call Time must elapse before a call record is generated.<br />

2. <strong>Telephone</strong> ports 1 and 2 are in Station to Timer Class of Service, Class 1 by default. All other ports are in Station<br />

to Timer Class of Service, Class 2 by default (R3000 or higher).<br />

3. When a system is upgraded from R2500 or lower, the Start Time Selection is reset to the default value during<br />

the upgrade process (R3000 or higher).<br />

4. For copper trunks only. Not supported on digital trunks.<br />

1~4<br />

Setting<br />

Data<br />

___________________________________________________________________________________<br />

2 - 10 Memory Blocks