<strong>Electra</strong> <strong>Elite</strong> <strong>IPK</strong> Document Revision 4<br />

___________________________________________________________________________________<br />

6-5 Trunk Group Mode Copy Assignment<br />

General Description<br />

Use this Memory Block to enable copying data from one Trunk group to another Trunk<br />

group or multiple consecutive Trunk groups.<br />

Display<br />

<strong>Programming</strong> Procedures<br />

1 Go off-line.<br />

Title<br />

Example: To copy data of Trunk Group 01 to Trunk Groups 10~14:<br />

1. Enter the original Trunk Group. Using the dial pad, press KA.<br />

2. Press G .<br />

Original<br />

Group No.<br />

Trunk<br />

(01~32)<br />

T R K G P – – ><br />

T I M E D I S P L A Y<br />

2 Press LK6 + LK5 to access the Memory Block.<br />

3 Enter the Trunk group to be copied.<br />

Setting<br />

Data<br />

Use the following to enter data:<br />

�<br />

K~Ito enter numeric data<br />

H to clear all data when placed at cursor position<br />

T R K G P 0 1 – – ><br />

T I M E D I S P L A Y<br />

3. Enter the Trunk Group. Using the dial pad, press AK~ AD.<br />

– – > T R K G P –<br />

T I M E D I S P L A Y<br />

Copy Mode<br />

6<br />

Tenant<br />

5<br />

Data No.<br />

—<br />

___________________________________________________________________________________<br />

<strong>Programming</strong> <strong>Manual</strong> 2 - 625