AMMONIUM SULFATE CAS N°: 7783-20-2
AMMONIUM SULFATE CAS N°: 7783-20-2
AMMONIUM SULFATE CAS N°: 7783-20-2
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
OECD SIDS<br />
<strong>AMMONIUM</strong> <strong>SULFATE</strong><br />
2. PHYSICO-CHEMICAL DATA ID: <strong>7783</strong>-<strong>20</strong>-2<br />
DATE: 18.04.<strong>20</strong>06<br />
study well documented<br />
Flag:<br />
Critical study for SIDS endpoint<br />
23-AUG-<strong>20</strong>05 (17)<br />
Value:<br />
at 25 degree C<br />
Method:<br />
other (calculated): MPBPWIN v1.40 (modified Grain Method)<br />
Year: <strong>20</strong>03<br />
Result:<br />
6.63E-22mmHg (=8.84E-<strong>20</strong>Pa)<br />
Reliability: (2) valid with restrictions<br />
calculated with standard program<br />
26-JAN-<strong>20</strong>04 (16)<br />
2.5 Partition Coefficient<br />
Partition Coeff.: octanol-water<br />
log Pow:<br />
= -5.1 at 25 degree C<br />
Method:<br />
OECD Guide-line 107 "Partition Coefficient (n-octanol/water),<br />
Flask-shaking Method"<br />
Year: 1988<br />
GLP:<br />
no<br />
Test substance: purity: 99%<br />
Reliability: (4) not assignable<br />
The OECD test method 107 applies only to pure, water soluble<br />
substances which do not dissociate or associate and which are<br />
not surface active. Therefore the validity of this method for<br />
ammonium sulfate is uncertain.<br />
Flag:<br />
Critical study for SIDS endpoint<br />
25-MAR-<strong>20</strong>03 (<strong>20</strong>)<br />
Partition Coeff.: octanol-water<br />
log Pow:<br />
= .48 at 25 degree C<br />
Method: other (calculated): LOGKOW, v. 1.66<br />
Reliability: (2) valid with restrictions<br />
accepted calculation method<br />
Flag:<br />
Critical study for SIDS endpoint<br />
26-JAN-<strong>20</strong>04 (21)<br />
2.6.1 Solubility in different media<br />
Solubility in:<br />
Value:<br />
Descr.:<br />
Water<br />
= 764 g/l at <strong>20</strong> degree C<br />
of very high solubility<br />
Reliability: (2) valid with restrictions<br />
data from standard reference book<br />
Flag:<br />
Critical study for SIDS endpoint<br />
30-JAN-<strong>20</strong>04 (14)<br />
UNEP PUBLICATIONS 61