<strong>Ipswitch</strong> <strong>WhatsUp</strong> <strong>Gold</strong> <strong>User</strong> <strong>Guide</strong><br />

3 Select an active monitor, then click Critical. The Critical Active Monitor properties<br />

appear.<br />

4 Select Enable critical monitor polling for this device.<br />

5 Under the Non-critical monitors list, select the monitor(s) that you would like polled<br />

first in the critical polling path, then click Critical.<br />

Tip: To remove a monitor from the Critical monitors list, select the monitor in the Critical<br />

monitors (polling order) list, then click Non-critical.<br />

6 Under the Critical monitors list, use the Up and Down buttons to place critical<br />

monitors in the order that you want the monitors polled. The first monitor is the first<br />

polled in the critical polling path. If the first monitor goes down, all monitors below it are<br />

not polled until the first monitor returns to an up state. If you select only one critical<br />

monitor, this is the first and only critical monitor in the critical polling path; all noncritical<br />

monitors are not polled unless the critical monitor is in the up state. Additionally,<br />

if a critical monitor fails, all subsequent critical and non-critical monitors are forced into<br />

an unknown state until the critical monitor returns to an up state.<br />

Tip: The paragraph at the bottom of the dialog describes the critical monitor path as it is<br />

configured.<br />