OID/Instance. Select a SNMP counter by clicking the browse (...) button. After you<br />

select a counter, the OID and Instance fields will populate with the type and instance<br />

of the counter you select.<br />

Color. Select a color for the counter by clicking the browse (...) button. This color is<br />

used in the Web Performance Monitor graph for this specific counter. If you are<br />

graphing multiple counters, this color differentiates it from the other counters.<br />

Scale. Use this to change the magnitude of the graphed values. For example, a value<br />

of 100 with a scale of 0.1 will display as 10. A value of 2912 on a scale of 0.01 will<br />

display as 29.12. The raw polled value is multiplied by the scale to determine the<br />

actual graphed value. The default scale is 1.0.<br />

Tip: Scaling is useful when displaying multiple values on the same graph that have<br />

significantly different magnitudes.<br />

2 Click OK to save changes.<br />

APC UPS Active Monitor<br />

This monitor watches your American Power Conversion Uninterruptible Power Supply (APC<br />

UPS) device and alerts you when selected thresholds are met or exceeded, output states are<br />

reached, and/or abnormal conditions are met. For example, an alert can be sent when the<br />

UPS battery capacity is below 20%, when the battery temperature is high, when the battery is<br />

in bypass mode due to a battery overload state, and many other UPS alert conditions.<br />

Enter or select the appropriate information in the following fields.<br />

Name. Enter a name for the active monitor. This name is displayed in the Active<br />

Monitor Library.<br />

Description. Enter a short description for the monitor. This name is displayed next to<br />

the monitor name in the Active Monitor Library.<br />

Thresholds. Select the threshold(s) on which you want to be alerted. Refer to the APC<br />

UPS documentation for more information about the thresholds. By default, all of the<br />

thresholds are selected for use in the monitor. By default, the following output states<br />

are selected for use in the monitor:<br />

Battery Status<br />

Battery Capacity<br />

Battery Runtime<br />

Output Load<br />

Tip: Select a threshold, then click Configure to set its individual threshold settings.<br />