614 Alarm management<br />

Example : In this example, control_center is defined as an SNMP notification.<br />

// define an SNMP notification<br />

notification snmp control_center {<br />

address:="192.9.200.1";<br />

trap:="6.1";<br />

}<br />

.<br />

.<br />

.<br />

// send an SNMP notification to the control center with the same<br />

trap<br />

//format as the M1<br />

send(control_center,<br />

"1.3.6.1.4.1.562.50.1.2.1.0","Integer",$AlarmSeqNum, //<br />

AlarmSeqNo<br />

"1.3.6.1.4.1.562.50.1.2.2.0","OctetString",$DeviceTime, //<br />

Date&Time<br />

"1.3.6.1.4.1.562.50.1.2.3.0","Integer",$NormalizedSeverity,//<br />

Severity<br />

"1.3.6.1.4.1.562.50.1.2.4.0","Integer",nsOtm, //Name Space<br />

"1.3.6.1.4.1.562.50.1.2.5.0","OctetString",$ErrorCode//Error<br />

Code<br />

"1.3.6.1.4.1.562.50.1.2.6.0","OctetString",$Site, //Site<br />

"1.3.6.1.4.1.562.50.1.2.7.0","OctetString",$ComponentAddress,//<br />

<strong>System</strong><br />

"1.3.6.1.4.1.562.50.1.2.8.0","OctetString",$<strong>System</strong>Component,//<br />

<strong>System</strong> Component<br />

"1.3.6.1.4.1.562.50.1.2.9.0","OctetString",$CurrentTrapSource,/<br />

/Originating Agent<br />

"1.3.6.1.4.1.562.50.1.2.10.0","Integer",$TrapType,//Trap Type<br />

"1.3.6.1.4.1.562.50.1.2.11.0","OctetString",$AssocUser,//<br />

Associated User<br />

"1.3.6.1.4.1.562.50.1.2.12.0","OctetString" $OperatorData,//<br />

Problem Isolation Data1<br />

"1.3.6.1.4.1.562.50.1.2.13.0","OctetString" $ExpertData,//<br />

Problem Isolation Data2<br />

"1.3.6.1.4.1.562.50.1.2.14.0","OctetString" $Text//Problem<br />

Isolation Data3<br />

)<br />

The preceding notification should be framed as shown and include all OIDs; otherwise,<br />

the management station may not properly receive the notification. The third parameter,<br />

variable name, is different for each device. For example, ITG has the variable names for<br />

component address, text, and expert data set as “na.” Sample trap formats for all<br />

supported devices are included in “Sample Alarm Notification script file” on page -894<br />

of "Script file summary".”<br />

553-3001-330 Standard 3.00 August 2005