01.01.2015 Views

Suprem III - Stanford Technology CAD Home Page

Suprem III - Stanford Technology CAD Home Page

Suprem III - Stanford Technology CAD Home Page

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

-57-<br />

<strong>Suprem</strong>-<strong>III</strong> User´s Manual<br />

27. Loadfile Statement<br />

----------------------------<br />

The LOADFILE statement is used to input either a new structure to be processed, the physical and model<br />

coefficients to be used by the program, or both.<br />

LOADFILE<br />

FILENAME= ( ALL | COEFFICI | STRUCTUR )<br />

[ FORMATTE ]<br />

Name Type Description<br />

---- ---- -----------<br />

ALL Log Specifies that both the structure information and the model coefficients<br />

are to be input from the specified file.<br />

(unit: )<br />

(default: false.)<br />

(synonym: )<br />

COEFFICI Log Specifies that the coefficient information is to be input from the specified<br />

file.<br />

(unit: )<br />

(default: false.)<br />

(synonym: )<br />

FILENAME Char The name of the file from which the specified information is to be read.<br />

(unit: )<br />

(default: )<br />

(synonym: NAME)<br />

FORMATTE Log Specifies that the information in the file is formatted. If not specified<br />

then the information is assumed to be unformatted or binary.<br />

(unit: )<br />

(default: false.)<br />

(synonym: )<br />

STRUCTUR Log Specifies that the information describing the structure is to be input from<br />

the specified file.<br />

(unit: )<br />

(default: false.)<br />

(synonym: )<br />

The LOADFILE statement inputs two classes of information about the process that is to be simulated. The<br />

first class is the physical structure and impurity distributions of the materials to be simulated. This file is used as the<br />

starting point for subsequent processing steps. The other class of information consists of all of the physical and<br />

model parameters or coefficients used by the program.<br />

A LOADFILE statement may appear at any point in a processing sequence after the INITIALIZE statement<br />

and before the STOP statement. If both structure and coefficient information are to be input, it is recommended<br />

that an INITIALIZE statement be used instead of LOADFILE.