-82-<br />
<strong>Suprem</strong>-<strong>III</strong> User´s Manual<br />
CLEAR Log Causes the plot area to be cleared.<br />
(unit: )<br />
(default: true.)<br />
(synonym: )<br />
CMAX Num The maximum concentration value plotted.<br />
(unit: atoms/cmˆ3.)<br />
(default: 1x10ˆ21)<br />
(synonym: )<br />
CMIN Num The minimum concentration value plotted.<br />
(unit: atoms/cmˆ3.)<br />
(default: 1x10ˆ14)<br />
(synonym: )<br />
DEVICE Char Specifies the type of plot device used. If this is not specified, on a system<br />
with full gplot support the user’s terminal will be used if it has graphics<br />
capabilities or the default graphics device if it does not. On a system<br />
without full gplot support the device types are limited to those distributed<br />
with the code or added by the person providing local <strong>Suprem</strong>-<strong>III</strong><br />
support. This person should be contacted for a list of the devices available.<br />
(unit: )<br />
(default: See above.)<br />
(synonym: PLOTDEV)<br />
FILENAME Char Specifies that the plot output is to be re-routed to the named file.<br />
(unit: )<br />
(default: )<br />
(synonym: )<br />
LABEL Char Specifies the string to be plotted to the right of the plotted structure along<br />
with a short segment of the current linetype. If not specified then the<br />
type of data plotted is used.<br />
(unit: )<br />
(default: The type of data plotted.)<br />
(synonym: )<br />
LAYERn Log If not negated, specifies that the indicated layer is to be plotted. If negated,<br />
specifies that the layer is not to be included in the plot. If no layers<br />
are specified then all layers present in the current structure are plotted.<br />
If any layer is negated then all layers not explicitly negated are plotted,<br />
if any layer is specified and not negated then only those layers so specified<br />
are plotted.<br />
(unit: )<br />
(default: true.)<br />
(synonym: )<br />
LINETYPE Num Sets the line type used when plotting the impurity distribution. A solid<br />
line and various dotted and dashed line types are available.<br />
(unit: )<br />
(default: 1 i.e. solid line.)<br />
(synonym: )<br />
NET Log Specifies that the difference of the sum of the n-type and the sum p-type<br />
active or chemical impurity concentrations present in the structure is to<br />
be plotted.<br />
(unit: )<br />
(default: false.)