Sludge Treatment Project Engineered Container Retrieval and Transfer System December 2011<br />

1. Interior units, full-guarded, surface-mounted, heavy-duty type, with general-purpose<br />

NEMA ICS 6, Type 1 enclosure.<br />

F. Emergency Manual Operation: Equip each electrically powered door with capability for<br />

emergency manual operation. Design manual mechanism so required force for door operation<br />

does not exceed 25 lbf.<br />

G. Emergency Operation Disconnect Device: Equip operator with hand-operated disconnect<br />

mechanism for automatically engaging manual operator and releasing brake for emergency<br />

manual operation while disconnecting motor without affecting timing of limit switch. Mount<br />

mechanism so it is accessible from floor level. Include interlock device to automatically<br />

prevent motor from operating when emergency operator is engaged.<br />

H. Motor Removal: Design operator so motor may be removed without disturbing limit-switch<br />

adjustment and without affecting emergency manual operation.<br />

2.7 DOOR ASSEMBLY<br />

A. Insulated Service Door: Overhead fire-rated coiling door formed with curtain of interlocking<br />

metal slats.<br />

1. Manufacturers: Subject to compliance with requirements, available manufacturers<br />

offering products that may be incorporated into the Work include, but are not limited to,<br />

the following:<br />

a. Cookson Company.<br />

b. Cornell Iron Works, Inc.<br />

c. McKeon Rolling Steel Door Company, Inc.<br />

d. Overhead Door Corporation.<br />

e. Raynor.<br />

f. Wayne-Dalton Corp.<br />

g. Windsor Door.<br />

B. Operation Cycles: Not less than 20,000.<br />

C. Fire Rating: 2 hours.<br />

D. Curtain R-Value: 4.5 deg F x h x sq. ft/Btu.<br />

E. Door Curtain Material: Galvanized steel.<br />

F. Door Curtain Slats: Flat profile slats of 2 and 5/8 inch center-to-center height.<br />

1. Insulated-Slat Interior Facing: Metal.<br />

G. Curtain Jamb Guides: Galvanized steel with exposed finish matching curtain slats.<br />