01.10.2013 Views

SECTION 033000 - CAST-IN-PLACE CONCRETE

SECTION 033000 - CAST-IN-PLACE CONCRETE

SECTION 033000 - CAST-IN-PLACE CONCRETE

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Sludge Treatment Project Engineered Container Retrieval and Transfer System December 2011<br />

B. Shop Drawings: Show fabrication and installation layouts of metal wall panels; details of edge<br />

conditions, joints, panel profiles, corners, anchorages, attachment system, trim, flashings,<br />

closures, and accessories; and special details. Distinguish between factory, shop, and fieldassembled<br />

work.<br />

C. Calculations: Provide fastener spacing and design to meet uniform pressure acting on panels.<br />

D. Samples: For each type of exposed finish required.<br />

1.4 <strong>IN</strong>FORMATIONAL SUBMITTALS<br />

A. Coordination Drawings: Exterior elevations, drawn to scale, and coordinating penetrations and<br />

wall-mounted items.<br />

B. Product test reports.<br />

C. Warranties: Sample of special warranties.<br />

1.5 CLOSEOUT SUBMITTALS<br />

A. Maintenance data.<br />

1.6 QUALITY ASSURANCE<br />

A. Installer Qualifications: An employer of workers trained and approved by manufacturer.<br />

B. Fire-Test-Response Characteristics: Provide metal wall panels and system components with the<br />

following fire-test-response characteristics as determined by testing identical panels and system<br />

components per test method indicated below by UL or another testing and inspecting agency<br />

acceptable to authorities having jurisdiction. Identify products with appropriate markings of<br />

applicable testing agency.<br />

1. Fire-Resistance Characteristics: Per ASTM E 119.<br />

C. Fire-resistive mineral wool core metal wall panels and system components that make up the<br />

envelope of the Sludge Loading Bay (Room 100) are Safety Significant, SSC’s (Structure,<br />

Systems or Components) based on UL 263 and ASTM E 119 fire resistance testing.<br />

1. All safety SSCs will be procured, inspected, accepted, and verified in accordance with the<br />

requirements of the Quality Assurance Program.<br />

D. Preinstallation Conference: Conduct conference at Project site.<br />

1.7 WARRANTY<br />

A. Special Warranty: Manufacturer’s standard form in which manufacturer agrees to repair or<br />

replace components of metal wall panel assemblies that fail in materials or workmanship within<br />

specified warranty period.<br />

Contract 44577 KW Annex - Rev. D 44577-CSI-SPEC-001 074219 - 2