Sludge Treatment Project Engineered Container Retrieval and Transfer System January 2012<br />

5. Calibration records and list of set points.<br />

1.6 QUALITY ASSURANCE<br />

A. Installer Qualifications: Automatic control system manufacturer's authorized representative<br />

who is trained and approved for installation of system components required for this Project.<br />

B. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70,<br />

Article 100, by a testing agency acceptable to authorities having jurisdiction, and marked for<br />

intended use.<br />

C. Comply with ASHRAE 135 for DDC system components.<br />

1.7 DELIVERY, STORAGE, AND HANDL<strong>IN</strong>G<br />

A. Factory-Mounted Components: Where control devices specified in this Section are indicated to<br />

be factory mounted on equipment, arrange for shipping of control devices to equipment<br />

manufacturer.<br />

B. System Software: Update to latest version of software at Project completion.<br />

1.8 COORD<strong>IN</strong>ATION<br />

A. Coordinate location of thermostats and other exposed control sensors with plans and room<br />

details before installation.<br />

B. Coordinate equipment with Division 28 Section "Fire Detection and Alarm" to achieve<br />

compatibility with equipment that interfaces with that system.<br />

C. Coordinate supply of conditioned electrical branch circuits for control units and operator<br />

workstation.<br />

D. Coordinate equipment with Division 26 Section "Panelboards" to achieve compatibility with<br />

starter coils and annunciation devices.<br />

E. Coordinate equipment with Division 26 Section "Enclosed Controllers" to achieve compatibility<br />

with motor starters and annunciation devices.<br />

F. Coordinate equipment with Division 26 Section "Variable-Frequency Motor Controllers" to<br />

achieve compatibility with motor starters and annunciation devices.<br />

1.9 EXTRA MATERIALS<br />

A. Furnish extra materials described below that match products installed and that are packaged<br />

with protective covering for storage and identified with labels describing contents.<br />

1. Maintenance Materials: One thermostat adjusting key.<br />

Contract 44577 KW Annex - Rev. E 44577-CSI-SPEC-001 230900 - 4