Trouble Zone Type Third Area Assignment<br />

When a trouble zone is assigned to an area the zone must be programmed with the type of trouble zone<br />

(Trouble Silent, Trouble Bell etc).<br />

CP001:01 Type 3<br />

None<br />

Use the [1] and [3] keys to scroll the available zone types that can be assigned to the trouble zone. For more<br />

information about the list control data entry refer to the section List Control Data Entry (see page 344).<br />

Trouble Zone Fourth Area Assignment<br />

The trouble zone must be assigned to an area for it to perform any function in the system. By default ALL<br />

trouble zones are assigned to the predefined trouble area which is the last programmable area in the system. A<br />

trouble zone can be assigned in up to 4 different areas. A trouble zone can perform a different function in each<br />

area.<br />

CP001:01 Area 4<br />

None<br />

Use the [1] and [3] keys to scroll the available areas that can be assigned to the trouble zone. For more<br />

information about the list control data entry refer to the section List Control Data Entry (see page 344).<br />

Trouble Zone Type Fourth Area Assignment<br />

When a trouble zone is assigned to an area the zone must be programmed with the type of trouble zone<br />

(Trouble Silent, Trouble Bell etc).<br />

CP001:01 Type 4<br />

None<br />

Use the [1] and [3] keys to scroll the available zone types that can be assigned to the trouble zone. For more<br />

information about the list control data entry refer to the section List Control Data Entry (see page 344).<br />

Zone Type<br />

To access the Zone Type programming menu login using a valid installer code and then select [MENU, 4, 2, 2].<br />

The screen displays "Zone type to modify" as shown in the following example.<br />

Zone Type to<br />

modify: ZT001<br />

Every time you press the [ENTER] key, the next screen appears. The different screens are described in the<br />

following sub-sections.<br />

Zone Type Name<br />

If the selected zone type has a name associated (some zone types do not have a name associated with them)<br />

the name programming screen will be shown.<br />

ZT001 Name<br />

Delay<br />

To scroll zone types by name use the [] and [] keys. To modify or enter a new name for the selected zone<br />

type use the keypad as explained in section Entering Text and Names (see page 341) and press [ENTER].<br />

By default the zone name will be prefixed by an '*' this indicates that the name is an editable name in the<br />

system.<br />

PRT-CTRL-SE <strong>Protege</strong> <strong>System</strong> <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong> | PRT-CTRL-SE 101