Function Mode<br />

The function mode determines how this function operates with the system controller. By default a function is set<br />

to normal operation. Normal operation will mean the function is started if it was running when the system<br />

restarts or is completely powered down (AC Failure and Battery Failure). The Run Once mode of operation will<br />

allow the function to run once and then wait to be stopped and started by the user or operator.<br />

FN001 Func Mode<br />

Normal<br />

Use the [1] and [3] keys to scroll the function mode until you reach the normal selection and press [ENTER] to<br />

proceed to the next programmable option for the door control function. For more information about the list<br />

control data entry refer to the section List Control Data Entry (see page 344).<br />

Rex Zone Input<br />

The Request to Exit (REX) Input is connected to the Virtual Door's REX Zone. When this zone is closed the<br />

Lock PGM is activated and the door can be opened for the Max Open time when no alarms being generated.<br />

This zone should be configured as a digital zone, therefore disable the "EOL Resistor on zone input" option. If<br />

a Normally Closed REX button is used the zone should inverted option should be set for the zone to ensure<br />

pushing the button will generate the REX event.<br />

This zone must also be placed in an armed area for the Virtual Door to operate.<br />

FN001 REX<br />

Zone CP001:01<br />

Halted<br />

To modify the input Zone, use the settings as explained in section Entering Zones (see page 345).<br />

Door State Zone Input<br />

The Door Position input is connected to the Door State Zone. This should be configured so that when the<br />

door opens the zone opens. It may be necessary to invert the zone input to ensure this operation.<br />

This zone should be configured as a digital zone, therefore disable the "EOL Resistor on zone input" option.<br />

This zone must also be placed in an armed area for the Virtual Door to operate.<br />

FN001 Door State<br />

Zone CP001:01<br />

Halted<br />

To modify the input Zone, use the settings as explained in section Entering Zones (see page 345).<br />

Virtual Door Left Open Zone<br />

When programmed this zone is controlled by the Virtual Door Function such that when the door is left open<br />

longer than the Max Open time and a Door Left Open event is generated this zone will be opened. When the<br />

door closes, the zone will also close. Place this zone in a reportable area to enabled reportable events from<br />

the virtual door.<br />

FN001 Left Open<br />

Zone CP001:01<br />

Halted<br />

To modify the input Zone, use the settings as explained in section Entering Zones (see page 345).<br />

246 PRT-CTRL-SE <strong>Protege</strong> <strong>System</strong> <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong> | PRT-CTRL-SE