Dial Attempt Number Phone Number Dialed Result<br />

6 Phone Number 2 Fail<br />

7 Phone Number 2 Fail<br />

8 Phone Number 2 Fail (Trouble Zone CP001:06 Opened,<br />

Failure To Communicate)<br />

Alternate Dialing Attempts<br />

Alternate dialing is an option available in the majority of the reporting services and results in the reporting phone<br />

numbers programmed in the service being dialed in an alternative sequence. In the following example, a service<br />

is programmed with two telephone numbers (Phone 1 and Phone 2) and a backup telephone number. The<br />

number of dialing attempts is set to 8 and the Use Alternate Dialing Method option has been enabled.<br />

If alternate dialing is enabled for the reporting service it is recommended that the monitoring company is<br />

informed and that they can make the appropriate programming arrangements.<br />

Success After 5th Dialing Attempt With Phone Number 1<br />

In the following example, the <strong>Controller</strong> was able to communicate with the central station with the programmed<br />

phone number 1 on the 5th attempt. As can be seen the back up phone number is dialed on each alternative<br />

failure. This is an extreme example most reports would have been received on the backup phone typically on<br />

the second attempt.<br />

Dial Attempt Number Phone Number Dialed Result<br />

1 Phone Number 1 Fail<br />

1 Back Up Phone Number Fail<br />

2 Phone Number 1 Fail<br />

2 Back Up Phone Number Fail<br />

3 Phone Number 1 Fail<br />

3 Back Up Phone Number Fail<br />

4 Phone Number 1 Fail<br />

4 Back Up Phone Number Fail<br />

5 Phone Number 1 Success (Report OK)<br />

Success After 2nd Dialing Attempt With Phone Number 2<br />

In the following example, the <strong>Controller</strong> was able to communicate with the central station only after phone<br />

number 2 was dialed for the second time. This resulted in the opening of the reporting failure trouble zone as a<br />

result of the reporting failure. This is subsequently sealed on the next valid report.<br />

Dial Attempt Number Phone Number Dialed Result<br />

1 Phone Number 1 Fail<br />

1 Back Up Phone Number Fail<br />

2 Phone Number 1 Fail<br />

2 Back Up Phone Number Fail<br />

3 Phone Number 1 Fail<br />

3 Back Up Phone Number Fail<br />

206 PRT-CTRL-SE <strong>Protege</strong> <strong>System</strong> <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong> | PRT-CTRL-SE