Selecting a Elevator to Modify<br />

Each elevator is assigned a unique door number from 001 to 250. Your system will be limited to specific number<br />

of elevators that are defined in the selected profile. For information on profiles refer to the Advanced<br />

Programming Section (see page 207).<br />

Elevator to<br />

modify: EL001<br />

Type the appropriate 3-digit elevator number or use the [] and [] keys to scroll the available elevator<br />

numbers. When the desired elevator number appears on the screen, press [ENTER] to program the selected<br />

elevator number. The maximum number of elevators that can be programmed is limited by your system's<br />

memory and configured profile.<br />

Elevator Name<br />

If the selected elevator has a name associated (some elevators do not have a name associated with them) the<br />

name programming screen will be shown.<br />

EL001 Name<br />

*Elevator 001<br />

To scroll elevators by name use the [] and [] keys. To modify or enter a new name for the selected elevator<br />

use the keypad as explained in section Entering Text and Names (see page 341) and press [ENTER].<br />

By default the elevator name will be prefixed by an '*' this indicates that the name is an editable name in the<br />

system. Some elevators do not have names, this is limited by the system memory and the profile configured.<br />

General Options<br />

General options configure the elevator for various operational modes and functions.<br />

EL001 General<br />

[--------]<br />

To modify options, use the keypad as explained in section Entering Data Options (see page 344).<br />

Option 1 – Destination Reporting Mode Enabled<br />

• Enabled the elevator will operate in DRM mode allowing only one button to be selected by the user when<br />

the present their card.<br />

i<br />

When using the DRM mode the PRT-PX16 modules that are used for elevator control must have a<br />

PRT-PX16-DRI board attached to allow the connection of button feedback inputs.<br />

• Disabled the elevator will operate in normal mode with one badge activating the appropriate floor relays for<br />

the user.<br />

Option 2, 3, 4, 5, 6, 7 and 8 - Reserved<br />

• Reserved do not modify<br />

Enabling/disabling or modifying the settings of reserved options is not recommended.<br />

144 PRT-CTRL-SE <strong>Protege</strong> <strong>System</strong> <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong> | PRT-CTRL-SE