Reader Expander<br />

The reader expander selection programs the elevator to send the activation of floor information and floor<br />

selection to the reader expander programmed. You must also set the port number in the next screen to the<br />

appropriate port driving this elevator.<br />

EL001 Reader<br />

None<br />

Use the [1] and [3] keys to scroll the reader expanders that are available and press [ENTER] to select the<br />

expander displayed. For more information about the list control data entry refer to the section List Control Data<br />

Entry (see page 344).<br />

Reader Port<br />

The reader port selection programs the elevator to communicate on this port with the expander number<br />

selected above. You must also set the reader expander number in the previous screen.<br />

EL001 Port<br />

None<br />

Use the [1] and [3] keys to scroll the reader port and press [ENTER] to select the port displayed. For more<br />

information about the list control data entry refer to the section List Control Data Entry (see page 344).<br />

Floor Open Time<br />

The floor open time configures the amount of time that a floor will be activated for when it has been selected or<br />

the amount of time the floor relay will be activated for when the user has presented a card.<br />

EL001 Open<br />

time: 005 secs<br />

To modify the Floor open time (000 to 255 Seconds), use the keypad as explained in section Entering Decimal<br />

Numbers (see page 341) and press [ENTER].<br />

Destination Select Time<br />

The destination select time configures the amount of time that user has to select a floor when they present their<br />

card.<br />

EL001 Select<br />

time: 005 secs<br />

To modify the floor select time (000 to 255 Seconds), use the keypad as explained in section Entering Decimal<br />

Numbers (see page 341) and press [ENTER].<br />

Floor Configuration<br />

Each floor in an elevator can be assigned options, an unlock schedule and an area. These options configure<br />

how the floor will function. You must select the floor to modify for the elevator that you are programming.<br />

EL001 Floor to<br />

modify: FL001<br />

Type the appropriate 3-digit floor number or use the [] and [] keys to scroll the available floors for the<br />

elevator. When the desired floor number appears on the screen, press [ENTER] to program the selected floor.<br />

PRT-CTRL-SE <strong>Protege</strong> <strong>System</strong> <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong> | PRT-CTRL-SE 145