Re-Arm Delay<br />

Setting the re-arm delay will result in the area automatically re-arming after the re-arm timer has elapsed. This<br />

should be programmed for area's used to monitor and control system functions that should not be disarmed.<br />

This is also used to control vault and automatic teller machines when using the banking area functions to<br />

prevent an area from being disarmed for longer than a the time programmed.<br />

AR001 Re-arm on<br />

time: 030 mins<br />

To enter a re-arm delay time (000 to 250 minutes), use the keypad as explained in section Entering Decimal<br />

Numbers (see page 341) and press [ENTER]. For the re-arm timer to operate the re-arm option must be<br />

enabled.<br />

Arming/Disarming Schedule<br />

The arming and disarming schedule is programmed so that an area will be armed and disarmed according to a<br />

schedule that is assigned.<br />

The area will be disarmed at the start time and armed at the end time of the schedule.<br />

In the case that an area only requires to be disarmed program the start time with the time that is required to<br />

disarm and the end time of the schedule with --:--. This will mean the area will automatically disarm at the start<br />

time for the programmed days in the period.<br />

Do the same if the area requires to be armed only on schedule by programming the end period with the required<br />

time to arm and set the start time to --:--.<br />

AR001 Schedule<br />

None<br />

Use the [1] and [3] keys to scroll the schedule selection and press [ENTER] to select the schedule displayed.<br />

For more information about the list control data entry refer to the section List Control Data Entry (see page 344).<br />

Recent Close Time<br />

The recent closing time defines how long the system considers an armed area recently closed. If, after arming<br />

the area, an alarm is generated within the programmed period, the <strong>Protege</strong> <strong>System</strong> <strong>Controller</strong> transmits a recent<br />

closed message. For this feature to operate correctly the zone must have its report options enabled in the<br />

assigned zone type.<br />

AR001 Recent cls<br />

time: 000 secs<br />

To enter a recent closing delay time (000 to 250 minutes), use the keypad as explained in section Entering<br />

Decimal Numbers (see page 341) and press [ENTER]. Setting a value of 000 will result in no recent closing<br />

reports being sent for the area.<br />

Disarm Delay Time<br />

The disarm delay time is used in conjunction with the Automatic Teller Machine control and banking control<br />

functions. Setting a disarm delay time will cause the area to delay by the programmed delay time any access to<br />

the area.<br />

AR001 Disarm dly<br />

time: 000 mins<br />

To enter a disarm delay time (000 to 250 minutes), use the keypad as explained in section Entering Decimal<br />

Numbers (see page 341) and press [ENTER].<br />