Option 4 - 8 - Reserved<br />

• Reserved do not modify<br />

Enabling/disabling or modifying the settings of reserved options is not recommended.<br />

Reader Port 2 Function PGM<br />

You can assign a PGM or PGM group that is used by the multiple badge options.<br />

RD001 R2 Func<br />

pgm: --000:00<br />

To modify the PGM or PGM Group, use the settings as explained in section Entering PGM and PGM Groups<br />

(see page 345).<br />

Reader Communication Failure Card Reading Operation<br />

When the reader expander fails to communicate with the system controller it will default to allowing access<br />

through the controlled doors based on the offline communication failure configuration and the type of module<br />

that has been registered at the reader location. An intelligent reader expander device will always process users<br />

based on the internal offline database and the configuration settings have no affect unless the No Cards option<br />

is selected.<br />

RD001 Offline<br />

All Cards<br />

Option<br />

No Cards<br />

All Cards<br />

First Ten<br />

Site Code<br />

Function<br />

Setting no cards will prevent ANY access from a card reader in the event the module fails<br />

and goes offline. This is also applicable to the PRT-RDI2 and PRT-RDE2 modules.<br />

This will allow ANY card to enter a reader on the PRT-RDM2 and PRT-RDS2 however on<br />

the PRT-RDI2 and PRT-RDE2 only cards that have the correct access credentials<br />

according to the internal database at the module will be allowed access.<br />

This will allow UN00001 to UN00010 to have unlimited access to the reader inputs on the<br />

PRT-RDM2 and PRT-RDS2 however on the PRT-RDI2 and PRT-RDE2 only cards that<br />

have the correct access credentials according to the internal database at the module will<br />

be allowed access.<br />

During the operation of the PRT-RDM2 and PRT-RDS2 the application will store the site<br />

codes of cards that have been granted access to the door, the site code will be cached<br />

for a period of 7 days or until the card is denied access normally. Setting this option will<br />

allow ANY card with the same site code to access the readers on the PRT-RDM2 and<br />

PRT-RDI2 modules. The PRT-RDI2 and PRT-RDE2 only cards that have the correct<br />

access credentials according to the internal database at the module will be allowed<br />

access.<br />

Use the [1] and [3] keys to scroll the available offline communication settings. For more information about the list<br />

control data entry refer to the section List Control Data Entry (see page 344).<br />