SIA Level 2 Reporting Service<br />

To program the SIA level 2 reporting service ensure that the service that has been selected and is halted. Press<br />

the [ENTER] key until the display shows the service type selection screen. The SIA service comprises of 3 levels.<br />

The transmission of the information uses a line speed of 300 BAUD and requires a tonal acknowledge.<br />

SV001 Ser Type<br />

SIA (Level 2)<br />

Use the [1] and [3] keys to scroll the service types until you reach the SIA level 2 reporting selection and press<br />

[ENTER] to select the SIA level 2 reporting service type displayed and proceed to the next programmable option<br />

for the SIA level 2 reporting service. For more information about the list control data entry refer to the section List<br />

Control Data Entry (see page 344).<br />

Service Mode<br />

The service mode determines how this service operates with the system controller. By default a service is set to<br />

start with the operating system. Setting a service to "Start With The Operating <strong>System</strong>" (Start With O/S) allows<br />

the service to operate automatically, if the system controller is reset or restarts the service will automatically<br />

restart with the operating system. <strong>Manual</strong> control of the service can be set by using the <strong>Manual</strong> option for the<br />

service mode.<br />

SV001 Ser Mode<br />

Start with O/S<br />

Use the [1] and [3] keys to scroll the available operating modes and press [ENTER] to select the operating mode<br />

displayed. For more information about the list control data entry refer to the section List Control Data Entry (see<br />

page 344).<br />

SIA Client Code<br />

The SIA client code is used to identify the system to the remote monitoring company when a report is<br />

generated. The client code will accept hexadecimal numbers however this will be dependent on the ability of the<br />

receiver and should be verified before configuration.<br />

SV001 Client<br />

code: 000000<br />

Type the appropriate 6 digit client code, after each digit you must press [] and [] to move to the next digit.<br />

When the desired client code is entered, press [ENTER] to save the programmed setting and move to the next<br />

screen. For more information about hexadecimal data entry refer to the section Hexadecimal Data Entry (see<br />

page 343).<br />

i<br />

When using a 4 Digit Account code program the account code in the last 4 locations leaving the first 2<br />

set at 00.<br />

PABX Phone Number<br />

The PABX phone number is dialed to gain an outside line if the system is connected to a internal phone<br />

extension. The PABX phone number can also be programmed with a schedule in the case that between certain<br />

times the phone line is directly connected with an outside line.<br />

SV001 PABX<br />

None<br />

Use the [1] and [3] keys to scroll the available phone numbers and press [ENTER] to select the phone number<br />

displayed. To program a phone number select [MENU, 4, 7, 2]. For more information about the list control<br />

data entry refer to the section List Control Data Entry (see page 344).<br />