Automation Control Point<br />

An automation control point allows this zone type to control an automation point in response to a zone opening<br />

or closing. An automation point can be assigned to many different functions such as gardening irrigation, lighting<br />

circuits, CBus Circuits and any PGM Output. You must configure the appropriate options to trigger the<br />

Automation point.<br />

ZT001 Automate<br />

None<br />

Use the [1] and [3] keys to scroll the available automation points and press [ENTER] to select the automation<br />

point displayed. For more information about the list control data entry refer to the section List Control Data Entry<br />

(see page 344).<br />

Zone Type Alarm Options<br />

Alarm options for the zone type configure the operation of the zone type when an alarm, restore and tamper are<br />

generated.<br />

ZT001 Alarm<br />

[12345---]<br />

To modify options, use the keypad as explained in section Entering Data Options (see page 344).<br />

Option 1 - Process Alarms<br />

• Enabled the zone type will process alarms from the zone that it is assigned.<br />

• Disabled the zone type will perform no function on an alarm being generated.<br />

Option 2 - Process Tamper 24HR Alarm<br />

• Enabled the zone type will process tamper alarms from the zone that it is assigned.<br />

• Disabled the zone type will perform no tamper processing.<br />

Option 3 - Entry Delay<br />

• Enabled the zone type will start an entry delay timer for the assigned area when the zone generates an<br />

alarm.<br />

• Disabled the zone type will not perform any entry delay actions.<br />

Option 4 - Entry Delay Follow<br />

• Enabled the zone type will allow this zone to generate alarms during the entry delay however it will generate<br />

an alarm if the alarm condition occurs outside the entry delay period.<br />

• Disabled the zone type operates normally.<br />

Option 5 - Exit Delay Follow<br />

• Enabled the zone type will allow this zone to generate alarms during the exit delay however it will generate<br />

an alarm if the alarm condition occurs outside the exit delay period.<br />

Use this feature to prevent 'Sitters' from re-entering a building that is assumed to be secure during a long<br />

arming process.<br />

• Disabled the zone type operates normally.<br />

Option 6 - Shorten Exit Delay Timer On Restore<br />

• Enabled the zone type will shorten the exit delay timer on an area to five seconds when the zone restores.<br />

Use this feature to reduce the arming time of an area.<br />

• Disabled the zone type operates normally.<br />