Analog Input/Output Expander<br />

The Analog expander will report trouble zones from 1 to 8 on the first 2 modules, all modules above address<br />

AE002 will be reported using the default code of 999.<br />

Zone Number Contact ID Code Reporting Point Number<br />

AE001:01 145 (Module Tamper) 949<br />

AE001:02 312 (Analog Voltage Low) 950<br />

AE001:03 312 (Auxiliary Fuse) 951<br />

AE001:04 140 (General Alarm) 952<br />

AE001:05 140 (General Alarm) 953<br />

AE001:06 140 (General Alarm) 954<br />

AE001:07 140 (General Alarm) 955<br />

AE001:08 143 (Module Offline) 956<br />

AE002:01 145 (Module Tamper) 957<br />

| | | | | | | |<br />

AE002:08 143 (Module Offline) 964<br />

AE003:01 145 (Module Tamper) 999<br />

| | | | | | | |<br />

AE250:16 143 (Module Offline) 999<br />

In the above table a reporting code of 999 indicates that the trouble zone is outside the maximum trouble zones<br />

that can be reported for the module type.<br />

SIA Level 2 Standard Zones<br />

The following tables show the reporting codes for the zones when the SIA Level 2 reporting format is used<br />

(Table 000, Default). The standard table is suited to both access control and burglary installations as it allows<br />

the reporting of all points available in the system.<br />

Control Panel Zones<br />

The control panel will report all zones from 1 to 16 using any of the available table configurations.<br />

Zone Number Alarm Code Restore Code Reporting Point Number<br />

CP001:01 BA BR 0001<br />

CP001:02 BA BR 0002<br />

CP001:03 BA BR 0003<br />

CP001:04 BA BR 0004<br />

CP001:05 BA BR 0005<br />

CP001:06 BA BR 0006<br />

CP001:07 BA BR 0007<br />

CP001:08 BA BR 0008<br />

CP001:09 BA BR 0009<br />