Service Type<br />

ModBUS<br />

ModBUS (Remote)<br />

Monitor Phone<br />

Function<br />

The ModBUS slave protocol allows the communication and control of objects (Zones,<br />

Areas, PGM's, Doors etc.) from a standard industrial automation package such as<br />

Citect, Wonderware, The FIX and DAQ Factory. There are many other products that<br />

support the ModBUS protocol and will communicate with the <strong>Protege</strong> <strong>System</strong>.<br />

The ModBUS remote protocol communicates with a remote <strong>Protege</strong> <strong>System</strong> using<br />

intelligent on-demand reporting for large scale, wide area monitoring using a standard<br />

SCADA package while adding the ability to protect and control access to the remote<br />

outstation.<br />

Monitors the onboard modem for incoming upload/download connections, performs<br />

line fault monitoring and pc callback functions.<br />

This service will share the modem with the Contact ID, SIA and ModBUS Remote and<br />

other services that use the onboard modem if they are running.<br />

Report IP<br />

Serial Printer<br />

SIA<br />

Upload Direct<br />

Viz IP<br />

Allows the <strong>Protege</strong> <strong>System</strong> controller to send alarm and activation information over an<br />

IP connected network. The Report IP Service supports multiple formats and allows<br />

the connection to third party reporting if required.<br />

Prints events to a standard serial communication port. Can be programmed to only<br />

print specific event groups or events from a specific area. Option to send<br />

Hexadecimal Events and PC acknowledgement functions for use with Third Party<br />

OEM event retrieval systems.<br />

Sends alarms, tests and events using the SIA Level 2 reporting format to a monitoring<br />

station capable of receiving the SIA Level 2 format. This service shares the modem<br />

with the Contact ID, Monitor Phone and ModBUS remote services if they are running.<br />

Provides the interface between the <strong>System</strong> <strong>Controller</strong> and the <strong>Protege</strong> <strong>System</strong><br />

Management Suite Software. This service must always be present.<br />

Provides an interface for <strong>Protege</strong> <strong>System</strong> <strong>Controller</strong>s to communicate to a DVR over<br />

IP that has the VizIP IP communication protocol. This service maps PGMs on the<br />

<strong>System</strong> <strong>Controller</strong> to the alarm outputs from the DVR, eliminating the need to have<br />

physical wiring connections from the DVR to the <strong>Protege</strong> <strong>System</strong> <strong>Controller</strong>.<br />

The services require specific programming for the type that is selected, the following details the programming<br />

information for each service type.<br />

Contact ID Reporting Service<br />

To program the contact ID reporting service ensure that the service you have selected it halted. Select the<br />

service type selection screen as shown below for Contact ID.<br />

SV001 Ser Type<br />

Contact ID<br />

Use the [1] and [3] keys to scroll the service types until you reach the contact ID selection and press [ENTER] to<br />

select the contact id service type displayed and proceed to the next programmable option for the contact ID<br />

service. For more information about the list control data entry refer to the section List Control Data Entry (see<br />

page 344).<br />

154 PRT-CTRL-SE <strong>Protege</strong> <strong>System</strong> <strong>Controller</strong> <strong>Reference</strong> <strong>Manual</strong> | PRT-CTRL-SE